8. Troubleshooting
Safety in Maintenance and Repairs
Before starting any repairs or maintenance on the Pan Feeder System observe the following safety steps:
1. Isolate the whole of the system from the electricity supply by switching OFF the power isolator and
locking it.
2. Keep the key in the possession.
3. When making any repairs to the auger, be aware that it may be under some degree of tension.
Avoid touching the auger with the hands until you are sure that it is loose at all points. Use a suitable
tool to check the auger.
4. Do not reconnect the power supply until all work is completed and all guards are correctly refitted.
Problem
Checks
Corrective Action
1. Spinner control pan will not
shut system OFF.
a. Check to see if the feed has stopped the
paddle of the spinner motor and the
green light is OFF, but the feed line
motor still runs.
a. Replace the solid state relay.
b. Check to see if the feed has stopped the
paddle of the spinner motor and the
green light is ON, but the feed line motor
still runs.
b. Replace the PC board.
c. Check to see if feed reaches the spinner
motor, but the paddle continues to “drill”
through the feed.
c. Change the pulse settings to a lower
pulse, using the DIP switches on the
PC board.
d. Check to see if the feed bridges over the
throat instead of falling into the pan.
d. Make sure nothing is blocking the throat,
and that feed is dropping into the center
of the throat.
2. Spinner control pan will not
restart system when feed is
called for.
a. Check to see if the spinner motor in the
end control pan does not spin and the
yellow light is ON with a bright pulse
every 5-10 seconds.
a. Replace the spinner motor.
b. Check that the spinner motors, in a
system with a center house control pan,
does not spin and the yellow light is ON
with a bright pulse every 5-10 seconds.
b1. Make sure the voltage at the spinner
motor in the center house pans is
between 17 and 24 volts, if center house
pans are used.
b2. Make sure the field wiring is correct to
the center house control pans, if there is
no voltage.
b3. Use a heavier gauge wire, if the voltage
is very low.
c. Check to see if the spinner motor does
not spin and the yellow light is not ON.
c. Replace the PC board.
d. Check that the spinner motor spins, but
the feed line motor does not come ON,
and the green light comes ON after a
10 second delay.
d. Replace the solid state relay.
Содержание Hi-Lo
Страница 1: ...PNEG 250 Hi Lo and PRO 1 Pan Feeder Installation and Operation Manual PNEG 250 Date 12 02 09 ...
Страница 2: ...2 PNEG 250 Pan Feeders ...
Страница 36: ...7 Installation 36 PNEG 250 Pan Feeders Program Chart Figure 7AZ ...
Страница 37: ...7 Installation PNEG 250 Pan Feeders 37 Figure 7BA ...
Страница 38: ...7 Installation 38 PNEG 250 Pan Feeders Figure 7BB ...
Страница 39: ...7 Installation PNEG 250 Pan Feeders 39 Figure 7BC ...
Страница 40: ...7 Installation 40 PNEG 250 Pan Feeders Figure 7BD ...
Страница 41: ...7 Installation PNEG 250 Pan Feeders 41 Figure 7BE ...
Страница 60: ...7 Installation 60 PNEG 250 Pan Feeders Figure 7CQ ...
Страница 80: ...9 Parts List 80 PNEG 250 Pan Feeders Hi Lo End Control and Drive Mount 7100113 ...
Страница 82: ...9 Parts List 82 PNEG 250 Pan Feeders Micro Switch Center House Control Pan 7101534 ...
Страница 84: ...9 Parts List 84 PNEG 250 Pan Feeders Micro Switch End Control Pan 7101482 ...
Страница 90: ...9 Parts List 90 PNEG 250 Pan Feeders Feed Level Control Switch 7051400 ...
Страница 92: ...9 Parts List 92 PNEG 250 Pan Feeders Flex Flo Hopper Level Control Assembly ...
Страница 94: ...9 Parts List 94 PNEG 250 Pan Feeders Flex Flo Level Control Switch FLX 3802 ...
Страница 96: ...9 Parts List 96 PNEG 250 Pan Feeders Winching and Miscellaneous Accessories ...
Страница 98: ...9 Parts List 98 PNEG 250 Pan Feeders Winching and Miscellaneous Accessories Continued ...
Страница 102: ...9 Parts List 102 PNEG 250 Pan Feeders Winch Assembly Parts ...
Страница 106: ...9 Parts List 106 PNEG 250 Pan Feeders Switch Box E170 A1007 ...
Страница 108: ...108 PNEG 250 Pan Feeders 10 Wiring Diagram Rooster Power Winch Wiring Diagram ...