1. Safety
PNEG-308
Purafire
9
General Safety Information
1. Observe all safety, installation, operation and maintenance instructions before placing this heater
into service.
2. Installation of the heater(s) must comply with all applicable local, state and national codes.
3. This heater is NOT to be used to heat human living quarters.
4. DO NOT use in unventilated areas. Adequate ventilation is essential to safe operation. When
operating this heater, the forming of moisture droplets on cold surfaces or the feeling of nausea or
headaches is an indication of improper ventilation. Prolonged exposure to improperly ventilated
areas can result in asphyxiation or death.
5. DO NOT use this heater in areas where gasoline or other liquids having flammable vapors, or in
heavy dust laden atmospheres (i.e. mills, granaries, etc.). Failure to follow this warning can result
in an explosion.
6. DO NOT attach any inlet and/or discharge duct work other than approved accessories to the
heater. Excessive static pressure may cause this heater to overheat and/or cause excessive
amounts of combustion products to be discharged into the space.
7. Maintain proper clearances to combustible material. See heater nameplate for specific clearance.
8. DO NOT operate this heater with improper fuel. See heater nameplate for fuel specified.
9. DO NOT position fuel cylinder in path of discharge air.
10. This heater will not operate correctly unless the gas supply pressure is properly regulated. Under no
circumstance should the gas pressure supplied to the heater be greater than 14" W.C. (1/2 PSI).
11. All gas high-pressure regulators must be vented to the outside of the building with no reduction in
size of the vent piping. The vent piping should be designed to prevent the entry of water, insects
or other foreign material that could cause blockage.
12. DO NOT connect this heater to the supply gas line unit all piping has been pressure tested and
purged. Damage to the gas valve may result.
13. DO NOT grip gas valve body with pipe wrench or vise. Damage may result causing gas leakage.
Use inlet or outlet bosses or a special body wrench.
14. The air inlet openings are located on the bottom of the heater. DO NOT operate heater while it is
sitting on its base.
15. This appliance is equipped with a three-prong (grounding) plug and should be plugged directly into
a properly grounded three-prong receptacle.
16. DO NOT bypass any safety devices. Replace or repair defective components before placing heater
into service.
17. Protect the power cord from coming into contact with sharp edges or the base of the heater.
18. DO NOT repair, handle or move unit while hot or operating.
19. Before each use of this heater, an inspection of the heater, power cord, hose assembly (if used),
and gas piping is essential to ensure safe and satisfactory heater operation. This inspection should
be performed by qualified service personnel at least once a year. Use only the factory specified
hose assembly for field replacement.
20. The hose assembly shall be visually inspected on an annual basis. If it is evident that there is
excessive abrasions or wear, or the hose is cut, it must be replaced prior to the heater being put
into operation. The replacement hose assembly shall be that specified be the manufacturer.
Содержание C225
Страница 21: ...PNEG 308 Purafire 21 6 Wiring Diagrams 120V Models Figure 6A...
Страница 22: ...22 PNEG 308 Purafire 6 Wiring Diagrams 220V Models Figure 6B...
Страница 23: ...PNEG 308 Purafire 23 7 Wiring Harness Wiring Harness Assembly Figure 7A...
Страница 32: ...32 PNEG 308 Purafire 11 Parts List C225 NG LP Galv Purafire 120V 60 Hz...
Страница 34: ...34 PNEG 308 Purafire 11 Parts List C225 X1 NG LP Galv Purafire 220V 50 60 Hz...
Страница 36: ...36 PNEG 308 Purafire 11 Parts List C80M NG LP Galv Purafire 120V 60 Hz...
Страница 38: ...38 PNEG 308 Purafire 11 Parts List C80M X1 NG LP Galv Purafire 220V 50 60 Hz...
Страница 56: ...56 PNEG 308 Purafire NOTES...