9. Start-Up
PNEG-308
Purafire
29
Burner Operation
1. Set the operating thermostat (optional) to its highest setting.
2. Verify that inlet and discharge air are not restricted.
3. Place the selector switch located on the electrical control enclosure to the “ON” position.
NOTE:
The ignitor warm-up cycle is approximately 10 seconds prior to the automatic gas valve being
energized. The automatic gas valve will remain energized for a maximum of 6 seconds during
the ignition cycle. If a burner fails to ignite, the automatic gas valve will close. However, the
blower will remain ON, purging the heater of any gas vapors. After 8 seconds of purging, the
burner will again try for ignition. If the burner fails to ignite on the third try for ignition, the
blower will purge the heater of any gas vapors, shut down and go into a lockout mode. The
heater must be turned OFF for 3 seconds and then turned back ON to reset the lockout mode.
Pre-purging of the gas line is required to avoid nuisance lockout.
4. Verify the burner operation by checking that the flame is evenly spread.
5. Place the selector switch to the “OFF” position.
6. Repeat steps 3 through 5 several times to ensure proper ignition and burner operation.
7. Depending on when the heater is to be placed in service, follow the LIGHTING and/or
SHUT DOWN instructions as applicable.
Adjustment of Heater Input (Optional for C80M)
The model C80M is supplied with a manual modulating valve on the outlet of the automatic gas valve,
prior to the orifice elbow, to permit the adjustment of the heating input between the minimum of
40000 BTU/Hr and the maximum input of 80000 BTU/Hr.
Содержание C225
Страница 21: ...PNEG 308 Purafire 21 6 Wiring Diagrams 120V Models Figure 6A...
Страница 22: ...22 PNEG 308 Purafire 6 Wiring Diagrams 220V Models Figure 6B...
Страница 23: ...PNEG 308 Purafire 23 7 Wiring Harness Wiring Harness Assembly Figure 7A...
Страница 32: ...32 PNEG 308 Purafire 11 Parts List C225 NG LP Galv Purafire 120V 60 Hz...
Страница 34: ...34 PNEG 308 Purafire 11 Parts List C225 X1 NG LP Galv Purafire 220V 50 60 Hz...
Страница 36: ...36 PNEG 308 Purafire 11 Parts List C80M NG LP Galv Purafire 120V 60 Hz...
Страница 38: ...38 PNEG 308 Purafire 11 Parts List C80M X1 NG LP Galv Purafire 220V 50 60 Hz...
Страница 56: ...56 PNEG 308 Purafire NOTES...