Installing the Tubular Motor to Motor Mount
1. Lift the end of drive pipe (50) with the tubular motor (89). Press the tubular motor (89) into the
bracket that is installed on the motor mount (118).
2. Make sure that the limit switches are accessible.
Motor Cable Positioning
Depending on the application, the motor cable can pass through the center side of the motor head. Raise
the yellow cover plate, re-position the cable, and then press the cover plate into position.
Figure 3-41
Motor cable positioning
50
Drive pipe
118
Motor mount
89
Tubular motor
Mounting the Motorized Tube
The motor brackets (96) are equipped with a clip ring. This clip ring does not have to be removed for
installation. Press the tubular motor (89) axially into the motor bracket (96) in any of six positions, so that
the limit switch adjustment buttons are always easily accessible.
Figure 3-42
Mounting the motorized tube
89
Tubular motor
96
Tubular motor bracket
4801-5405
Unitized System Komfort Kool
49