48” MEGA

-FLOW CONE FAN 

Fan & Cone Installation

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.  Disconnect power source before installing or 

servicing fan.  Failure to disconnect power 
source can result in property damage, 
serious injury, or death. 

2.  When connected to an automatic controller, 

FAN MAY START AT ANY TIME. 

3.  IMPORTANT!  Before Operating Fan, Inspect 

Fan For any Object That May Obstruct Blade 
Rotation. 

WARNING! 

BEFORE INSTALLING 

1.  Inspect fan for damage in transit.  Check for 

loose, missing, or damaged parts. 

2.  If there are any missing parts or if there is 

any shipping damage, do not attempt to 
operate fan.  Contact your Distributor. 

MAINTENANCE 

1. 

Read WARNING statements before proceeding.

 

2. 

Blades, motor, and wire guards should be cleaned 
periodically to decrease vibration and ensure 
maximum fan life.  Remove dirt with a dry brush or 
compressed air.  DO NOT SPRAY MOTOR WITH 
WATER OR CLEANING FLUIDS. 

3. 

Fan performance may be greatly reduced by 
damaged or dirty shutter.  Clean and inspect shutter 
periodically to ensure maximum fan performance.

 

When this fan is used in a life support ventilation 

system where failure could result in loss or injury, 

the user should provide adequate backup 

ventilation, or accept the risk of such loss or injury. 

IMPORTANT! 

 

48” Mega-Flow Fan & Cone 

1.  Fan should be securely mounted to wall.  Refer to 

mounting instructions on sheet 3 of this manual. 

2.  The cone and wire guard must always be installed for 

your protection. 

National safety codes require that guards be installed 
if within 7 feet (2.1 m) of floor or within reach of 
personnel or livestock. 

3.  If thermostat is used, connect fan power cord to 

controller. 

INSTALLATION 

Содержание 48 INCH MEGA-FLOW CONE FAN

Страница 1: ...proceeding 2 Blades motor and wire guards should be cleaned periodically to decrease vibration and ensure maximum fan life Remove dirt with a dry brush or compressed air DO NOT SPRAY MOTOR WITH WATER...

Страница 2: ...rformance of this extended warranty Conditions and Limitations THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE SPECIFICALLY GSI MAKES NO FURTHER WARRANTY OF...

Страница 3: ...N S T R U C T I O N S FAN SPACING WITH CONE Fan Housing Cone Center to Center Spacing Fan Size Spacing 48 63 0 160 0 cm Fan Size Fan Model Rough Opening Width Height 48 Mega Flow Cone Fan 54 75 139 c...

Страница 4: ...arefully lift fan into position 2 Securely attach fan to wall with screws not provided NOTE Route power cord through access port in top of cabinet as shown CAUTION Fan Is Heavy Do Not Attempt To Lift...

Страница 5: ...ing TEK screws WARNING During Cone Installation Be Sure That Fan Motor Is Not Plugged Into Any Power Source Always Double Check Power Sources 1 Lay cone pieces flat with their flanges pointed up Refer...

Страница 6: ...ific cone size 6 Install three corner brackets to joints of panel assembly as shown in Figure 4 Attach each corner bracket to two holes in the cone nearest the small cone opening with 1 4 bolts and nu...

Страница 7: ...ve a tight fit of cone around orifice 10 While supporting cone assembly attach a top corner bracket to fan housing Position bracket install 1 TEK screws into fan housing through holes in bracket See F...

Страница 8: ...of shutter to access latch Fasten latch located inside fan housing into slot in flange of shutter Firmly lock down latch Repeat procedure to latch opposite side of shutter Shutter Fits Onto Intake Si...

Страница 9: ......

Страница 10: ...Copyright 2015 by The GSI Group LLC Printed in the USA...

Отзывы: