background image

Technical Support: 1-800-721-9243 (M-F 8:00 am - 4:30 pm CST)

Under-Sink Water Filter 

Installation and Operating Instructions 

Model US-600

A

¸

Before proceeding with installation, choose the appropriate filter cartridge and install in 

housing according to the cartridge replacement instructions (p. 2). See Filter Cartridge 

Selection Guide on p. 3 to determine the best cartridge for your filtration needs.

Specifications

Pressure Range: 

30–125 psi (2.1–8.6 bar)

Temperature Range: 

40–100°F (4.4– 37.7°C)

Parts Included 

•  filter housing assembly with built-in mounting bracket and quick-connect fittings
• 

3

8

 inch (10 mm) tubing

•  (2) quick-connect elbows
•  SW-5

A

 housing wrench

•  D-20

A

 cartridge 

 

Precautions

 Do not use with water that is microbiologically unsafe or of unknown 

quality without adequate disinfection before or after the system. Systems certified for 

cyst reduction may be used on disinfected waters that may contain filterable cysts.

 

Filter must be protected against freezing, which can cause cracking of the 

filter and water leakage.

 

The rubber O-ring provides the water-tight seal between the cap and the 

bottom of the housing. It is important that the O-ring be properly seated in the groove 

below the threads of the housing or a water leak could occur.

 

Because of the product’s limited service life and to prevent costly repairs or 

possible water damage, we strongly recommend that the bottom of all plastic housings 

be replaced every ten years. If the bottom of your housing has been in use for longer 

than this period, it should be replaced immediately. Date the bottom of any new or 

replacement housing to indicate the next recommended replacement date.

NOTE:

 

•  For cold water use only.
•  Make certain that installation complies with all state and local laws and regulations.
•   The contaminants or other substances removed or reduced by the selected cartridge 

are not necessarily in your water. Ask your local water municipality for a copy of 

their water analysis, or have your private well tested by a reputable water testing 

lab. 

•    After prolonged periods of non-use (such as during a vacation) it is recommended 

that the system be flushed thoroughly. Let water run for 5–6 minutes before using.

•   The filter cartridge used with this system has a limited service life. Changes in 

taste, odor, color, and/or flow of the water being filtered indicate that the cartridge 

should be replaced.

Tools Required

•  screwdriver
•  file
•  pencil
•  pipe cutter or hacksaw

Optional Materials

•   faucet (FCT-1) for use with D-40

A

 filter 

cartridge

•   Some harmless bacteria may attack cellulose media cartridges (such as the D-10). 

If your cartridge seems to disintegrate or develops a musty or moldy odor, switch to 

a synthetic media cartridge or call Technical Support.

 

 

 

Installation

NOTE:

•   For standard under-sink installation on 

3

8

 inch (10 mm) cold water line (copper or 

PVC pipe).

•   Please read all instructions and precautions before installing and using your  

US-600A under-sink filter.

•   Install filter cartridge in filter housing before proceeding with installation (see Filter 

Cartridge Replacement on p. 2). 

•  Numbered diagrams correspond with numbered steps. 

1.   (A)

 Turn off cold water supply and open nearest faucet to release pressure in pipes 

before starting installation. Place a tray or towels under the cold water line to catch 

excess water. 

(B)

 Select location under sink where filter is to be mounted. Use 

mounting bracket as a template to mark screw locations. Mount filter in marked 

location using mounting bracket. 

   

NOTE:

 

(C)

 Allow 1

1

2

 inches (33 mm) clearance below housing to enable filter 

cartridge changes.

2.

    Using a pipe cutter or hacksaw, remove a 3-inch (76 mm) section of pipe 

(A)

 from 

the 

3

8

 inch (10 mm) cold water line. Deburr ends of remaining pipe with a file. 

(B)

 

Push a quick-connect elbow onto each end of remaining cold water line. Be sure to 

push elbow onto pipe until you hit a hard stop.

3.

   Determine the lengths of tubing needed to connect the inlet and outlet sides of 

filter to the quick-connect fittings on the cold water line. Measure tubing short 

enough to prevent kinking. Cut the tubing squarely between the closest set of 

black guide arrows. Assemble as shown in Figure 3 on page 2, inserting tubing into 

appropriate inlet or outlet quick-connect fitting until it stops (inlet and outlet are 

marked “IN” and “OUT” on cap). 

 

 NOTE:

 When cut between a set of black guide arrows, the tubing should be pushed 

The US-600

A

 with D-20

A

 has been tested and certified by NSF International against 

NSF/ANSI Standard 42 for the reduction of Aesthetic Chlorine Taste and Odor.

Systems tested and certified by NSF International with cartridges D-10, D-20

A

, D-30

A

and D-40

A

. See Performance Data Sheet, in manual, for specific claims.

 

01020691  REV A  06/09

1

A

B

C

1

2

"

2

A

B

Содержание US-600A

Страница 1: ...hanges in taste odor color and or flow of the water being filtered indicate that the cartridge should be replaced Tools Required screwdriver file pencil pipe cutter or hacksaw Optional Materials faucet FCT 1 for use with D 40A filter cartridge Some harmless bacteria may attack cellulose media cartridges such as the D 10 If your cartridge seems to disintegrate or develops a musty or moldy odor swit...

Страница 2: ...to fill a bucket of water first to allow you to clean housing after it has been removed B Locate and remove large O ring 1 wipe clean of lubricant and set aside Discard used filter cartridge 2 Rinse out bottom of filter housing and fill 1 3 full with water Add 2 tablespoons of bleach and scrub bottom of housing with nonabrasive sponge or cloth Rinse thoroughly Lubricate O ring with clean silicone ...

Страница 3: ... Class I filter life in gallons months 250 3 1000 12 1000 12 600 6 service flow rate gpm Lpm 1 0 3 8 1 0 3 8 0 9 3 4 0 6 2 3 Filter cartridge life varies depending on filter type usage and water conditions Flow rates measured at 60 psi 4 1 bar If not plumbed into separate tap flow rate may be less than 0 5 gpm for direct connect systems NOTE Substances reduced are not necessarily in your water Fil...

Страница 4: ...ater treatment device s listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants Cysts Turbidity Asbestos None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants Do not use where water is microbiologically unsafe or with water of unknown qualit...

Страница 5: ...nta Necesaria destirnillador fila lápiz cortatubos o sierra para metales Materiales Opcionales grifo FCT 1 para uso con el cartucho filtrante D 40A filtrante se debe reemplazar Alguna bacteria innocua puede atacar el cartucho hecho con agente celuloso p ej El D 10 Si parece que su cartucho filtrante se des integra o adquiere un olor a moho cambie a un cartucho filtrante hecho con agente sintético ...

Страница 6: ...ar los pocillos después de que los quite B Localice y quite la arandela redonda grande 1 límpiala del lubricante y póngala a un lado Deseche del cartucho filtrante usado 2 Enjuague el pocillo y llénelo con 1 3 de agua Agregue 2 cucharadas de descoloran te y restriegue el pocillo con una esponja o un trapo sin abrasivo Enjuague lo completamen te Tiene que lubricar la arandela redonda con grasa de s...

Страница 7: ...nes meses 250 3 1000 12 1000 12 600 6 Régimen de Flujo drante servicioLpm 1 0 3 8 1 0 3 8 0 9 3 4 0 6 2 3 Duración del cartucho filtrante varía dependiendo en su clase uso y condiciones del agua Régimen de flujo medido a 60 psi 4 1 bar Si no esta conectado en linea separadas los índices de corriente pueden ser menos de 0 5 gpm que es para sistemas que se conectan directo NOTA substancias reducidas...

Страница 8: ...ulligan International Company The water treatment device s listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants Cysts Turbidity Asbestos None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants Do not use where water is microbiologically uns...

Отзывы: