FILTER REPLACEMENT

These drinking water systems must be maintained according
to the manufacturer’s instructions, including timely 
replacement of filter cartridges. Follow the guidelines below
to determine when the filter cartridge must be replaced in
each system. Refer to Figure 3 for the service sequence.

Preferred™ 150 Filter

The filter cartridge must be replaced after every 750 gallons
or one year of use (whichever comes first), or whenever
there is a change in taste or odor or a noticeable decrease in
flow. 750 gallons of water use is roughly equivalent to using
2 gallons of water daily for one year.

Preferred™ 250 Filter

The filter cartridge must be replaced after every 1000 gallons
or one year of use (whichever comes first), or whenever there
is a change in taste or odor or a noticeable decrease in flow.
1000 gallons of water use is roughly equivalent to using 2-1/2
gallons of water daily for one year.

Preferred™ 350 Filter

The filter cartridge must be replaced after every 300 gallons
or one year of use (whichever comes first), or whenever there
is a change in taste or odor or a noticeable decrease in flow.
300 gallons of water use is roughly equivalent to using 1-1/2
gallons of water daily for six months. Conforms to NSF/ANSI
53 for VOC reduction. See Performance Data Sheet for 
individual contaniments and reduction performance.

Replacement Cartridge Part Numbers

Preferred 150 Filter Cartridge

01-0028-68

Preferred 250 Filter Cartridge

01-0028-69

Preferred 350 Filter Cartridge

01-0028-70

Replaceable components and service parts are available
through your local independent Culligan dealer. To learn
the name of your nearest dealer, contact:

Manufactured by:

CULLIGAN INTERNATIONAL COMPANY

One Culligan Parkway

Northbrook, IL 60062

USA

(847) 205-6000

http:\\www.culligan.com

WALL

W

ALL

W

ALL

45°

45°

Illustration A
Right Wall
Mounting

Illustration B
Back Wall
Mounting

Illustration C
Left Wall
Mounting

Figure 2

Figure 3

CARTRIDGE

REMOVAL

1. Shut off water supply.

Open serviced faucet
to relieve pressure.

CARTRIDGE

INSTALLATION

1. Align cartridge lug

with head label.

2. Turn cartridge to the

left as far as possible.

2. Holding head firmly,

press cartridge fully
into head.

3. Holding head firmly,

pull cartridge down-
ward and out of head.

3. Turn cartridge to right

until rotation stops.

4. Turn water on and run

water for 3 minutes to
purge cartridge of air.

45°

Head can
be rotated
a maxi-
mum of
45° from
wall.