Culligan MC405 Скачать руководство пользователя страница 9

0:00

Lift off this cover and connect the 

jack plug of the power lead to the 

control box behind the front panel

Rigid plastic 3/4" overflow pipe (not supplied with the softener) should be connected to 
the push fit elbow at the rear of the cabinet (see page 6). Run the pipe downhill to the 
outside of the building. Take care that the overflow does not discharge where damage 
could occur. 

If the water softener is fitted in a cellar or basement, the overflow can be run to a 
storage tank. Do not elevate the overflow hose. Do not use jointing cement on the fitting. 

4 .   O ve r f l ow   c o n n e c t i o n s

5. Electrical connections

For added safety, peace of mind and ease of installation, your water softener is powered 
by low voltage via a plug in transformer. This transformer must be connected to a fused 
switched socket.  Plug the transformer into the socket with the switch in the OFF position. 

8

Now place the water softener salt in the brine cabinet. Use care cubes (tablet salt)  
or block salt only, this is available from your local Waterside dealer.

7. Blending control

6. Filling the brine cabinet, salt usage and salt alar m

All machines are factory set to produce 
water that  is soft. If you prefer water 
which is less soft, turn the  blending knob 
on the left side of the valve anti-clockwise 
until the water meets your requirements. 

Notes on salt usage

Your water softener will only perform effectively if there is salt in the brine cabinet during 
the regeneration process. It is therefore essential that the salt level does not fall lower 
than 150mm in depth when measured from the base of the brine cabinet.

N.B. The softener requires no priming, add no water to the brine tank.

During regeneration, salt will not enter your water system as the salt used in the 
regeneration process is rinsed safely away to drain.

Your water softener is equipped with a low salt alarm, this monitors your salt usage and 
sounds an audible alarm while displaying the low salt error code "SALt" when your salt 
level falls to the minimum level. 

To reset the salt alarm fill the system with salt and 

press the  

     

key.

T

T

P

A

R

 

W

O

9. Switching on for the first time

"

Check that the inlet / outlet hoses or couplings are properly connected i.e. inlet-to-inlet, 

outlet-to-outlet.

"

The by-pass arrangement should be in the open position i.e. the inlet and outlet valves 
closed, by-pass valve open. Mains stop valve open.

"

Check that the Brine Cabinet contains salt.

"

Check that the water softener is connected to the drain and the overflow pipe is 
connected. The drain and overflow 

must not

 be linked to each other.

8. Testing for the water hardness in your area

Water hardness can vary  from one location to another. To determine the hardness of the 
water feeding your water softener (un-softened supply)  use the hardness test kit supplied. 

"

Fill the test bottle 

.

"
"

"

supplied to the fill line with water from a hard water tap

Add the tablets to the solution one tablet at a time.
Shake the bottle in between and keep adding tablets to the water until the solution turns 
from wine red to blue, record the number of tablets as you go.
Using the data table supplied with your kit, match up the number of tablets with the 
hardness. You will need this figure when programming your water softener in the next 
section of this manual.

 9

P

A

R

T

 T

W

O

"

Gently open the inlet valve so that water flows into the resin vessel.

"

Switch on the power, you will hear the valve move quietly into the start position. When 
the positioning  process has been completed (which can take up to 10 minutes) you will 
hear the movement stop, the valve has now reached its start position in preparation for 
the programming procedure.

"

Close the by-pass valve.

"

Gently open the outlet valve.

"

Check for leaks, take corrective action to stop leaks  if required.

"

Your water softener is now on line and you may start the valve programming procedure 
set out in the next section of this manual. 

 

Содержание MC405

Страница 1: ...the softening process 4 5 Installation and operating considerations 6 Installation layout PART TWO 7 8 Installing your water softener 9 Water hardness test Programming procedure 10 PART THREE Troubles...

Страница 2: ...system design is based on the extensive experience of Culligan in the UK Rotary valve means less moving parts for greater reliability Flow rates suitable for use on conventional and modern plumbing s...

Страница 3: ...Soft water Water inlet To drain Brine pick up Rinse water to drain Hard water SOFTENING CYCLE REGENERATION CYLCE RINSING CYCLE Periodically these resin beads are automatically cleaned and regenerated...

Страница 4: ...sible dependant on the incoming water pressure Please remember the weight of your new water softener will considerably increase once installed and filled with salt Therefore please ensure your chosen...

Страница 5: ...unt of sodium it has been calculated that 1 pint of softened water contains a similar amount of sodium as two slices of white bread or pint of milk Water that is used for mixing powdered milk for babi...

Страница 6: ...bush for 15mm pipework Key to the diagram A Non return valve B Pressure reducing valve where required C Inlet valve D Bypass valve E Outlet valve 6 PART ONE A B C E D Mains stop valve Drinking water...

Страница 7: ...the valve will confirm the direction of flow Connections can be made with either conventional copper tube and fittings or the high flow flexible hoses supplied ensure hoses are not kinked as this may...

Страница 8: ...from your local Waterside dealer 7 Blending control 6 Filling the brine cabinet salt usage and salt alarm All machines are factory set to produce water that is soft If you prefer water which is less...

Страница 9: ...ne with water from a hard water tap Add the tablets to the solution one tablet at a time Shake the bottle in between and keep adding tablets to the water until the solution turns from wine red to blue...

Страница 10: ...h a value of 300 parts per million of hardness minerals keys to adjust the setting to match that of the one you obtained identified earlier See page 9 for details Pressing the set key once enters the...

Страница 11: ...ed Remember to check the salt level in the brine cabinet weekly 11 PART H EE T R cc bs OR Fig4 4 SETTING THE TYPE OF SALT USED see Fig4 To operate effectively your water softener must be set to the ty...

Страница 12: ...within the specified operational parameters the water level should not reach the overflow connection If however an overflow situation occurs please refer to the troubleshooting section on page 13 to d...

Страница 13: ...BRINE CABINET REACHES OVERFLOW Is the line pressure within the specification of the water softener Connect a pressure gauge to a water outlet and check the pressure is between 1 7 5 0 bar 7 1 Pressure...

Страница 14: ...e If yes this is normal wait until the recharge is complete 3 There should be no flow to drain in the service position Isolate the softener and call for service 9 9 PROBLEM EXCESSIVE SALT USAGE Check...

Страница 15: ...CATION TABLE MC450 MC550 50 50 30 35 24 28 10 10 1 4 2 2 5 5 1 7 1 7 49 49 5 5 230 230 12 12 3 4 3 4 1 2 1 2 Model Maximum peak flow rate L min Maximum continious flow rate L min Basic flow rate flow...

Страница 16: ...or it representatives Any defect caused by malicious or wilful action negligence misuse or third part interference Any defect or damage occasioned by fire lightening explosion flood storm frost impact...

Отзывы: