M1 RO Installation
5
Cat. No. 01022940
M1 RO Installation
Unpacking the M1 RO
This manual, the warranty, and registration card are packed in the control assembly box. Please complete the registration
card and mail it promptly.
NOTICE
Examine each unit component carefully to check for loose or damaged parts. Report any apparent
or concealed shipping damage to the freight carrier immediately.
Materials Required
To install the system, the following items are required:
1. Level
2. Drill
3. Screws for mounting the bracket for the main plumbing assembly
4. Screwdrivers, including a small, flat-bladed (1/8” wide) screwdriver for wiring
5. Adjustable wrench
6. Tubing;
All—Nat 1/2” Feed Water and Product Water Tubing, P/N 00901801
All—Nat 3/8” Product Concentrate (Waste) Water Tubing, P/N 00444973
7. Bucket calibrated for taking flow rates
8. Clean rags
9. Thermometer
10. Stopwatch with a second hand
11. Portable Total Dissolved Solids meter
12. Safety glasses
Location
Series M units are designed for wall mounting so that all components are accessible for maintenance and monitoring.
The wall you choose for mounting the unit must be capable of supporting at least 130 pounds. See the assembly section
below for installation detail.
A 120 VAC/60 Hz/1 Phase grounded electrical receptacle with 15 amp fuse protection is required for use with the six-foot,
three-wire power cord.
NOTICE
Do NOT use any bolt size smaller than 1/4" diameter.
The unit must be located near a drain able to handle 10 gallons per minute (37.9 liters/min). This is in addition to the flow
from any other water treatment equipment.
CAUTION! The system must not be located near any corrosive chemicals which may cause fail-
ure of the plastic or metal parts of the unit. In addition, do not locate the unit where the
temperature may exceed the feed water temperature limits.