Aqua-Sensor Guidelines
65
Cat. No. 01024821
Appendix A Aqua-Sensor Guidelines
Aqua-Sensor Application Guidelines
Table 11.
Aqua-Sensor Application Guidelines
Parameter
Value
Hardness (gpg as CaCO3)
7 - 99 (See Notes 1 & 2)
Soluble iron (ppm as Fe)
< 2 (See Note 3)
Manganese (ppm as Mn)
< 0.5 (See Note 4)
Hardness versus Salt Dosage
See Table 18 and Note 2
TDS to Hardness Index
TDS hardness (as CaCO3) <10 (i.e., hardness must be at least 10% of TDS; see Note 5)
Temperature, °F
Any within equipment’s operating range
Alum and phosphate
Anecdotal evidence indicates potential foulant; effect has not been confirmed
experimentally
Commercial cell: distance between
sensing and reference cell pairs
6 inches (See Note 2)
Hardness vs. Salt Dosage
Table 12.
Hardness vs. Salt Dosage
Hardness (gpg as CaCO3)
Recommended Salt Dosage (lbs/ft3)
7-10
5-6
10-15
6-8
15-25
8-9
25-50
9-11
50-75
11-12
75-99
12-16
Resin Bed Depths and Estimated Capacity Per Inch at Various Salt Dosages
Table 13.
Resin Bed Depths and Estimated Capacity Per Inch at Various Salt Dosages
Model
Tank
Size
Resin
Qty
Depth of
Resin (in.)
Grains Capacity
per inch (10 lb/
ft³ salt dosage)
Grains Capacity
per inch (6 lb/ft³
salt dosage)
Grains Reserve
Capacity@10 lb/
ft³ salt dosage
Grains Reserve
Capacity@ 6 lb/ft³
salt dosage
HE-060
14x47
2
22.5
2227
1782
13363
10690
HE-090
16x53
3
25.8
2909
2327
17453
13963
HE-120
16x65
4
34.4
2909
2327
17453
13963
NOTE
1. Although the Aqua-Sensor device has been used successfully on water with hardness as low as 3 gpg, there is an increased
risk of missed signal (no regeneration) when the hardness is less than 6 gpg.
2. For each tank diameter, there is a specific volume of resin in the space between the cell pairs. The capacity of that resin is
influenced by hardness and salt dosage. Any combination of flow rate and hardness that causes the hardness front to pass
through that volume of resin in less than 6 minutes will result in the sensor failing to detect the need to regenerate. In general,
the volume of resin between the cell pairs on commercial units will permit a proper signal at or below the continuous flow
rating when raw water hardness is less than 50 gpg. At higher hardness levels, it may be necessary to reduce the flow rate to
assure adequate sensor signal duration.
3. If precipitated or bound iron is present it must be removed before the softener.
4. Manganese can deposit on the sensor electrodes, particularly on the upper pair, causing missed signals (no regeneration).
Periodic cleaning may be needed to maintain satisfactory performance.
5. Adequate signal strength has been demonstrated at ratios as high 14 but signal strength diminishes with decreasing TDS to
hardness index.
6. Amount shown is based on the distance between the referencing cell pairs. Reserve capacity at salt dosages less than 15 lbs
per cubic foot are shown for reference purposes only and may not provide adequate representation of actual capacity per inch
of bed depth for operational purposes.