Average

USEPA

Minimum

Average

 Influent

SDWA

2

Reduction

 Percent

Percent

Substance

 Concentration

MCL (mg/L)

Requirement

Removal

Removal

Arsenic

2

0.03 +/- 10%

0.025

96.6%

98.0%

Barium

10.0+/- 10%

2.0

90.0%

90.0%

Cadmium

0.03 +/- 10%

0.005

90.0%

96.4%

Hexavalent Chromium

0.30 +/- 10%

0.1

86.7%

86.7%

86.6%

Trivalent Chromium

0.30 +/- 10%

0.1

85.7%

85.7%

Copper

3.00 +/- 10%

1.3

96.5%

99.2%

Cysts

6

>50,000/ml

99.95%

99.99%

99.99%

Fluoride

8.0 +/- 10%

1.5

89.8%

95.2%

Lead

0.15 +/- 10%

0.010

97.0%

98.1%

Nitrate plus Nitrite (both as N)

30.0 +\- 10%

10.0

Nitrate

3

27.0 +/- 10%

10.0

74.03%

80.4%

Nitrite

3.0 +/- 10%

1.0

68.3%

75.8%

Radium 226/228

4

25pCi/L +/- 10%

5pCi/L

80.0%

80.0%

Selenium

0.10 +-/10%

0.05

93.02%

96.8%

Product

TDS Reduction

System Daily Prod. Rate

Average Maximum

Average

Prod. Rate w/o Storage

USEPA

Inffluent

Effluent

Minimum

Effluent

Average

 Tank

to Pressurized

Tank to

SDWA

Conc.

Conc.

Percent

Conc.

Percent

  Size

Storage Tank

Atmosphere

 MCL (mg/L)

(mg/L)

(mg/L)

Removal

(mg/L)

Removal

2 gallon

12.8 gpd (48.45L)

30 gpd

187

776

160

79%

112

85.5%

3 gallon

12.1 gpd (45.8L)

30 gpd

187

770

100

87%

70

90.9%

9 gallon

11.7 gpd (44.2L)

30 gpd

187

758

82

89%

65

91.4%

* This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern.

TESTING CONDITIONS (Complete Systems)
Temperature:

 77°F ± 2°F

pH:

 7.5 ± 0.5

Pressure:

 50 psi

Turbidity:

  < 1 NTU

This system has been tested and shown to operate at its calculated recovery rating under standard test
conditions.

DIMENSIONS
Filter Assembly

7.5” W x 3” D x 16.5” H (20 cm W x 8 cm D x 42 cm H)

Storage Tank

-  Standard

9” Diameter x 15” H (23 cm Diameter x 38 cm H)

- Medium

11” Diameter x 15” H (28 cm Diameter x 38 cm H)

- Large

15.5” Diameter x 22” H (40 cm Diameter x 56 cm H)

The 

Good Water Machine

 models listed above have been tested according to ANSI/NSF Standard 58 for effective

reduction of TDS, arsenic, barium, cadmium, hexavalent and trivalent chromium, copper, cysts, fluoride, lead, radium
226/228 and selenium as verified and substantiated by test data. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system as specified in ANSI/NSF 58.

16

1. While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressures, temperatures, and
other substances, which may be found in your water.
2. This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine.
3. Nitrate units are not certified for nitrate/nitrite reduction in water supplies with a pressure less than 4 psi (280 kPa). A booster pump is strongly
recommended.
4. Based upon testing methods using Barium as a surrogate.  All concentrations in pCi.l: pico cutirs/L.
5. United States Environmental Protection Agency (USEPA) Safe Drinking Water Act.
6. Includes Giardia, Lamblia, Entamoeba Histolyca and Cryptosporidium.

SUBSTANCE  REMOVAL

1

OUTPUT (Total Dissolved Solids (TDS) Reduction and Output Production

Содержание GoodWater Machine

Страница 1: ...Culligan GoodWater Machine DrinkingWater System Owners Guide ...

Страница 2: ...is product to perform properly The Good Water Machine contains replaceable particulate and activated carbon filters It also includes a replaceable reverse osmosis membrane filter which is critical for the effective reduction of Total Dissolved Solids The filtered water should be tested periodically to verify that the system is performing properly CULLIGAN INTERNATIONAL COMPANY One Culligan Parkway...

Страница 3: ...Your System 2 Component Description 2 Certified Performance 3 How to Use Your System 4 Performance Check 4 Installation Application Guidelines 5 Servicing Your System Service Schedule 7 Filter Replacement 7 Parts List 11 Service Log 12 Warranty 13 Table of Contents ...

Страница 4: ...Polishing Filter Cullar G Activated Carbon Dispensing Faucet Culligan Aqua Cleer Faucet Rotary Operation Stainless Steel and Resin Flow Passages with Built in Siphon Break Colors Polished Chrome or White Storage Capacity Standard Tank 2 gallons Medium Tank 3 gallons Large Tank 9 gallons Dimensions Filter Assembly 7 5 W x 3 D x 16 5 H Storage Tank Std 9 Diameter x 14 H Medium 11 Diameter x 14 H Lar...

Страница 5: ...MACHINE SYSTEM COMPONENTS Refer to Figure 1 page 6 Particle Filter The particle filter screens out dirt sand rust and other microscopic particles 15 times smaller than a grain of sand Activated Carbon Filter The activated carbon filter reduces elements that cause water to taste and smell unpleasant including the taste and odor of chlorine if present in your untreated water supply Reverse Osmosis M...

Страница 6: ...e models are accept able for treatment of influent concentrations of no more than 27 mg L Nitrate and 3 mg L Nitrite in combination measured as N and are certified for Nitrate Nitrite reduction only for water supplies with a pressure of 40 psig 280 kPa or greater This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine at the s...

Страница 7: ...ng properly To check the performance of your Good Water Machine it is necessary to measure the total dissolved solids TDS level of the filtered water This simple test can be done quickly by your dealer The Good Water SentryTM Water Quality Monitor is another way to keep track of your system s performance This optional accessory checks your drinking water each time you use the special faucet and si...

Страница 8: ...BLE 1 Influent Water Characteristic Pressure1 40 120 psi 280 827 kPa Temperature 33 100 F 1 38 C Total Dissolved Solids TDS 2 0 2500 ppm 0 2500 mg L pH 5 10 Chlorine3 0 3 ppm 0 3 mg L Chloramine 0 3 ppm 0 3 mg L Turbidity 0 10 NTU Hardness 0 20 gpg Iron 0 1 ppm 0 1 mg L Bacterial Quality Potable 1 Nitrate units are not certified for nitrate reduction in water supplies with a pressure less than 40 ...

Страница 9: ...7 1 Particle Filter 2 Activated Carbon Filter 3 Reverse Osmosis Membrane Filter 4 Polishing Filter 5 Manifold Assembly 6 Storage Tank 7 Air Gap Faucet 8 Cold Waterline 9 Water Shutoff 10 Drain Connector ...

Страница 10: ... Culligan recommends that you have your Good Water Machine serviced by your local Culligan Man You can rely on his or her experience and expertise to keep your system in top operating condition If you wish to service your system the filters are available from your Culligan dealer For replacement components please contact your local Culligan Dealer or 1 800 205 6000 for the dealer near you See the ...

Страница 11: ...embly and the polishing filter To disconnect the connector hold the collar against the fitting body and pull the tube from the fitting To assemble lubricate the tubing end with water and push the tubing into the connec tor until it bottoms out Be sure the tubing is smooth and free of abrasions otherwise a leak may result Fig 4 ...

Страница 12: ...is not enough RO water fill the container the rest of the way with soft water Cap the container and shake to mix NOTICE If any RO water remains after filling the container you may want to fill a pitcher with the drinking water as it will take several hours for the system to refill after servicing In any case leave the faucet open until the storage tank is empty and then close the faucet 3 Remove t...

Страница 13: ...nward twisting pull Discard any solution remaining in the housings 2 Open the particle filter cartridge bag half way being careful not to touch the filter element Lubricate the particle filter cartridge o rings with water and insert the cartridge into position 1 in the manifold 3 Fill housing 1 about 2 3 full of the diluted bleach solution from the 1 gallon container Assemble the housing to the ma...

Страница 14: ... external leaks 7 Rinse the manifold assembly for five minutes or until no chlorine is detected in the water passing to the drain Tighten the capillary assembly retaining screws 8 Check the performance of the system according to the procedure outlined in the Performance and Technical Information section of this manual Replace the RO membrane if necessary 9 Instruct the customer to discard the firs...

Страница 15: ... Large 01 0047 65 6 Screw 10 9 x 625 Pan Head Phil 00 4010 16 7 Particle Filter Element 00 4015 38 8 Capillary Assembly 01 0090 25 9 Reverse Osmosis Membrane Element AC 30 01 0074 02 10 Drain Adapter 01 0040 80 11 Activated Carbon Element 01 0125 80 Icemaker Tee 3 8 x 3 8 x 1 4 01 0047 28 Tubing Blue 1 4 O D 00 4021 84 3 8 O D 01 0002 87 Good Water Sentry Monitor 01 0047 12 Aqua Cleer Booster Pump...

Страница 16: ...ICED FILTER FILTER FILTER FILTER SANITIZED MODEL __________________SERIAL NO _______________________________ DATE INSTALLED ____________________________________________________ FOR SERVICE CALL CULLIGAN AT ____ _______________________________ Culligan Good Water Machine Service Log ...

Страница 17: ... or TDS levels may effect replacement frequency MSRP Particulate Prefilter Element 00 4015 38 30 00 Activated Carbon Prefilter Element 01 0008 27 or 01 0125 80 40 00 Activated Carbon Postfilter Element 01 0042 91 20 00 Reverse Osmosis Module 01 0074 02 150 00 If water production decreases or a noticeable taste change occurs contact your local Culligan Dealer A Culligan professional can determine i...

Страница 18: ...alculated recovery rating under standard test conditions DIMENSIONS Filter Assembly 7 5 W x 3 D x 16 5 H 20 cm W x 8 cm D x 42 cm H Storage Tank Standard 9 Diameter x 15 H 23 cm Diameter x 38 cm H Medium 11 Diameter x 15 H 28 cm Diameter x 38 cm H Large 15 5 Diameter x 22 H 40 cm Diameter x 56 cm H The Good Water Machine models listed above have been tested according to ANSI NSF Standard 58 for ef...

Страница 19: ...on local water conditions The substances reduced by this system are not necessarily in your water APPLICATION GUIDELINES The Good Water Machine is designed for use on potable water supplies meeting the guidelines outlined in Table 1 The system should be installed on your home s cold water line The flushing stream should discharge through an approved siphon break as illustrated in Figure 1 Installa...

Страница 20: ...PLIED WARRANTIES ARE LIMITED IN DURATION TO THE ONE YEAR PERIOD SPECIFIED ABOVE FOR THE PARTS DESCRIBED IN THIS LIMITED WARRANTY As manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a drinking water system Please understand that the quality of water supplies may vary seasonally or over a period of time and that your water usage rate ma...

Страница 21: ...11 20 page book saddle stitched Prints black ink on 50 offset white This page contains materials and DCO information IT DOES NOT PRINT AS PART OF THE DOCUMENT LET CHANGE BY APRVD DATE A DCO TPD JS 1 19 01 B DCO 2817 SMP JS 08 13 01 ...

Отзывы: