6
01021568
Set Hour (12PM–11AM)
SET HOUR
>12PM
The screen displays the hour setting. Press
to accept the information
displayed (and view the next setup screen), or press
to change the
setting.
Press
to change the hour (in this example, from 12PM to 10AM).
Press
to accept the selected hour and advance to the next setting,
SET
MINUTES
.
Set Minutes (0–60)
SET
MINUTES
>1
The screen displays the minutes setting. Press
to accept the informa-
tion displayed (and view the next setup screen), or press
to change
the setting.
Press
to change the minutes (in this example, from 0 to 20). Press
to accept the selected hour and advance to the next setting,
UNIT TYPE
.
Unit Type (Softener, Filter, or Resin + Carbon)
UNIT TYPE
>FILTER
The screen displays the unit type setting. Press
or
and then
to change the setting to Filter. Press
to advance to the next setting,
VALVE TYPE
.
Valve Type (HE 1, HE 1.25, HE 1.5, HE 1 Twin, HE 1.5 Twin, 4-Cycle, 5-Cycle, or Plat
Plus)
VALVE TYPE
> 4-CYCLE
The screen displays the valve type setting. Press
or
and then
to change the setting to
4-CYCLE
. Press
to advance to the next
setting,
UNITS
.
Units (US or Metric)
UNITS
>US INCH
The screen displays the units of measure setting. Press
to accept the
default setting (US INCH) and advance to the next setting,
MEDIA LIFE
.
Media Life
MEDIA LIFE
0
GALLONS
The screen displays the media life setting (0–100,000,000), which speci-
fies the estimated lifetime total flow of the filter media in gallons. Once
the total flow reaches the programmed media life, the controller displays
the alarm message
REPLACE FILTER MEDIA
. Press
or
and
then
to change the setting. Press
to advance to the next setting,
TOTAL CAPACITY
.