12
01021568
Manual
Regeneration
There are several conditions that will cause the control to trip a regeneration. The screen displays RE-
GEN TONITE when the control has signaled for a regeneration. REGENERATING is displayed while the
control is in regeneration. The following are conditions that will call for regeneration:
1.
When the Soft-Minder
®
meter has recorded the passage of a predetermined number of gallons.
2.
At the preset time, when the number of days without a regeneration is equal to the regeneration
interval (timeclock backup) setting.
3.
At the preset time, when
REGEN TONITE
is selected. The screen displays
REGEN TONITE
.
4.
Immediately, when the
REGEN NOW
is selected. The screen displays
REGENERATING
.
5.
Immediately, if power to the unit has been off for more than three (3) hours and time of day has
been restored.
6.
At the preset time based on
DAY-OF-WEEK
Regeneration setting.
Follow either procedure to initiate a manual regeneration.
Delayed Regeneration
Screen Display
Range
Changing the Setting
FILTERING
JAN-01-13 12:01P
N/A
1. At the
HOME SCREEN
, press
and hold for at least
three seconds, then release the button.
REGEN TONITE
JAN-01-13 12:01P
Regen
Tonite
2. The first line of the display will toggle between
FILTERING
and
REGEN TONITE
.
REGEN OFF
JAN-01-13 12:01P
Regen
Off
3. To cancel a delayed regeneration, press and hold the
for three (3) seconds, then release the button. The screen
displays
REGEN OFF
.
Immediate Regeneration
Screen Display
Range
Changing the Setting
FILTERING
JAN-01-13 12:01P
N/A
1. At the
HOME SCREEN
, press
and hold for at least ten
(10) seconds, then release the button.
REGEN NOW
JAN-01-13 12:01P
Regen
Now
2. The first line of the screen displays
REGEN NOW
. The fil-
ter will initiate an immediate regeneration.
REGENERATING
JAN-01-13 12:01P
N/A
3. The first line of the screen displays
REGENERATING
.