Outdoor Installation
57
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Appendix C - Outdoor Installation
Outdoor Select Series Enclosure
Outdoor rated Select Series have a water tight enclosure to protect the electrical and mechanical components from the weather.
Sealing Unit with Provided Screws
The control comes with 1/4 turn fastener for sealing the enclosure. Rotate the 1/4 turn fastener to open or close the
enclosure (See
). A hole is available at the bottom of the enclosure for an optional padlock if so desired.
WARNING!
Do not use an extension cord. Connect only to a suitably marked, covered GFCI receptacle location.
Figure 27.
Figure of Outdoor Enclosure
Placement
Refer to
for system placement outdoors.
•
Set the media tank on a solid, level surface near plumbing,
drain, and electrical connections. Media tank and plumbing
should be secured so the system can’t be knocked over.
•
The customer should provide a GFCI electrical outlet
suitable for outdoor use that is NOT controlled by a
switch that can be turned off accidentally.
•
For outdoor installation, only use an outdoor rated
power supply.
•
Power supply MUST be mounted on the wall at
least 1 foot above ground level. (See
)
•
Properly ground to conform with all governing
codes and ordinances.
•
Observe all state and local electrical codes.
•
P/N 01041744 plug-in 20-foot power supply is included,
is rated for outdoor installations, and is to be mounted
within 2-ft of the outdoor receptacle.
It
MUST
be mounted at least 1-ft above ground level
.
•
P/N 01041744 is an Outdoor rated 20-foot power
supply included with Outdoor systems. It is to be
mounted within 2-ft of the outdoor power receptacle.
•
For Outdoor use with a UL Listed Class 2 Direct
Plug-in Power Unit only.
• WARNING!
Use only Outdoor Power supplies for
Outdoor installations. DO NOT use Indoor Power
Supplies for Outdoor system installations.
1/4 Turn
Fastener
Holes For
Padlock
Enlarged
Area
VonnieP
Figure 28.
Outdoor System Placement