1. TERMS AND CONDITIONS 

 
Two Year Warranty 

All claims for parts or labor must be made directly through Culitek, and must include the model, the serial 
number, proof of purchase, date of installation, and all pertinent information supporting the alleged defect. 
In case of compressor replacement under warranty, either the compressor or compressor tag must be 
returned to Culitek, along with above listed information. 

Failure to comply with warranty policies will 

result in voided claims. 

 
 

Two Year Parts & Labor Warranty 

Culitek warrants all new refrigerated components, such as the cabinet and all parts, to be free from 
defects in materials or workmanship. Culitekʼs obligation under this warranty is limited to a period of two 
(2) years from the date of shipment from Culitek. All parts covered under this warranty that are defective 
within two (2) years from the date of shipment from Culitek are limited to repair or replacement (including 
labor charges) of defective parts or assemblies. The labor warranty shall include standard straight time 
labor charges only and reasonable travel time, as determined by Culitek. 

 
 

Additional Three-Year Compressor Warranty 

In addition to the two (2) year warranty, Culitek warrants its sealed compressor to be free from defects, in 
both material and workmanship, under normal and proper use and maintenance service for a period of 
three (3) additional years from the date of original installation, but not to exceed five (5) years. 
Compressors that have been determined to be defective from Culitek within this extended period will be 
either repaired or replaced with a compressor or compressor parts of similar design and capacity, 
according to Culitek‘s discretion. The three (3) year extended compressor warranty applies only to sealed 
parts of the compressor and does not apply to any other parts or components. This includes the cabinet, 
paint finish, temperature control, refrigerant, metering device, motor starting equipment, fan assembly, 
and other electrical components, etc. 

 
 

Compressor Warranty 

The (5) five-year compressor warranty will be void if the following procedure is not carefully adhered to: 

1.  System contains R290 refrigerant and lubricant. The lubricant has rapid moisture absorbing qualities. 

2.  Drier replacement is very important and must be changed when a system is opened for servicing. 

3.  Micron level vacuums must be achieved to insure low moisture levels in the system. 

4.  Compressor must be obtained through Culitek, unless otherwise specified in writing, through  

Culitek’s warranty department. 

 

 

 

Содержание F1SS

Страница 1: ...F2SS F3SS This manual contains important information regarding your Culitek unit Read this manual thoroughly prior to equipment setup operation and maintenance Failure to comply with regular maintena...

Страница 2: ...ntrol Unit 6 7 Handling 6 8 Installation Procedure 6 9 Connecting to Main Power Supply 6 10 Maintenance Instructions 7 11 Troubleshooting 7 12 Technical Service 7 13 Configuration Sketch Map 7 14 Oper...

Страница 3: ...n to the two 2 year warranty Culitek warrants its sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three 3...

Страница 4: ...is not responsible for repair or replacement of failed or damaged components resulting from electrical power failure the use of extension cords low voltage or voltage drops to the unit The two 2 year...

Страница 5: ...and pulling on the plug top p Do not pull out the cord or touch the power plug with wet hands Clean water or dust from the power plug and insert it with the ends of the pins securely connected p Do n...

Страница 6: ...tampering p Use of non original spare parts p Partial or total failure to comply with the instructions All electrical equipment can be hazardous to health Current standards and legal requirements must...

Страница 7: ...ear heat sources or in direct sunlight Remove the straps securing the cardboard packing the cardboard covering and the PET protection film before installation Clean the unit with mild detergent and th...

Страница 8: ...ean the condenser regularly a minimum of once every 4 months with a dry brush or vacuum cleaner 11 Troubleshooting Unit stops working light off Power supply failure Remedies Check that the plug is ins...

Страница 9: ...reases the displayed value In programming mode it browses the parameter codes or decreases the displayed value Lock or unlock keyboard To enter in programming mode To return to room temperature displa...

Страница 10: ...according to Cy e Cn P2 Evaporator probe failure Defrost end is timed HA Maximum temperature alarm Outputs unchanged LA Minimum temperature alarm Outputs unchanged EA External alarm Outputs unchanged...

Страница 11: ...Page 10 ELECTRICAL CONTROL CIRCUIT DIAGRAMS Refrigerator...

Страница 12: ...Page 11 ELECTRICAL CONTROL CIRCUIT DIAGRAMS Freezer...

Страница 13: ...Page 12 ELECTRICAL CONTROL CIRCUIT DIAGRAMS Three Door Freezer...

Страница 14: ...Page 13 TECHNICAL PARAMETERS Bottom Mount Reach Ins NOTE Technical data subject to changes...

Страница 15: ...Page 14 OFFICIAL APPROVAL RULES Conforms to UL STD 471 Certified to CSA STD C22 2 NO 120 Conforms to NSF AMSI STD 7...

Отзывы: