background image

5. Operating Your Grill (cont.)

12

5.3 Installing the gas cylinder

(The propane gas cylinder is not provided with  

the appliance.)
A gas cylinder complying with the requirements listed in 

section 4.2 must be obtained before the grill can operate. 

Connect the LP cylinder to the grill outdoors only.
Read and follow all direction on the cylinder. 
1. Turn the burner control knob to “OFF” position.
2.  Remove the protective caps from the cylinder valve and 

coupling nut, if present.

3.  Open grill lid and remove right side table for easier ac-

cess to regulator assembly.

4.  Grasp the grill handle nearest to the regulator with one 

hand, and with the other hand push the cylinder into the 

threaded regulator connector and turn clockwise until 

tight.

5. TIGHTEN BY HAND ONLY. Do not use tools.

REMOVAL OF THE GAS CYLINDER

1. Turn the burner control knob to “OFF” position.
2.  Grasp the grill handle nearest to the regulator with one 

hand, and turn the cylinder counterclockwise until it 

comes off. 

5.4 Checking for gas leak

  

m

 

DANGER

Check gas system for leaks to prevent fire or explosion 

hazard
1.  The “Leak Check” must be performed before lighting the 

grill and each time the cylinder is connected for use.

2. Do not smoke or allow other sources of ignition in the 

area while conducting a leak test.
3. Conduct the leak test outdoors in a well-ventilated area.
4. Do not use matches, lighters or a flame to check for 

leaks.
5.  Do not use grill until all leaks have been stopped, if 

you are unable to stop a leak, disconnect the propane 

supply, and call for gas application service or your local 

propane gas supplier.

Leak Check Method

1.  Make 2-3 oz. of leak solution by mixing one part liquid 

dishwashing soap with three parts water.

2.  Make sure control knob is in the “OFF” position.
3.  Spray or paint some leak solution on the cylinder and 

regulator connection.

4.  Inspect the solution at the connections, looking for 

bubbles. If no bubbles appear, the connection is secure.

5.  If bubbles appear, a leak is detected. Go to step 6.
6.  Disconnect the cylinder from the regulator, and reconnect. 

Make sure the connection is secure and no leak is found 

before using the grill.

7.  If you continue to see bubbles, DO NOT USE THE 

GRILL. Repeat the above process with a different LP 

cylinder. If leaks are still present, contact the customer 

service center.

13

A propane gas cylinder is required for operation. Use 

1.00ibs(465g). propane cylinder.
This Cuisinart grill is equipped with a regulator having a 

CGA No.600 cylinder connection 
1) Only cylinders marked “propane” must be used.
2)  The cylinders be disconnected when the appliances is 

not in use 

3)  Do not store a spare LP-gas cylinder under or near this 

appliance;

4) Never fill the cylinder beyond 80 percent full; and
5)  If the instructions in “-b12(a)” and “-b12(b)” are not  

followed exactly, a fire causing deathor serious injury 

may occur.

•  Propane cylinder size:D10cmXH20cm, Only cylinders 

marked “PROPANE” must be used.

•  The propane cylinder must be constructed and marked 

in accordance with the specification for LP-Gas cylinders 

of the U.S Department of Transportation (D.O.T) or the 

National standard of Canada, CAN/CSA-B339,Cylinders, 

spheres and Tubes for Transportation of Dangerous 

Goods.

•  Store spare fuel canisters in a well-ventilated area away 

from the grill.

• Do not puncture or burn fuel canister.

•  If the grill is not in use, the control knob must be turned 

to the “OFF” position to shut off the gas flow from the 

cylinder.

REMOVAL OF THE GAS CYLINDER 

(please see the 5.3 Installing the gas cylinder) “picture” 
1)  Turn the burner control knob to “OFF” position.
2)  Grasp the grill handle nearest to the regulator with one 

hand, and turn the cylinder counterclockwise until it 

comes off.

•  Do not store a spare propane cylinder under or near this 

grill. Never fill the cylinder beyond 80 percent full. If this 

instruction is not followed exactly, a fire causing death or 

serious injury may occur.

• Save the cylinder cap and reinstall when not in use.
•  Cylinder supply system must be arranged for vapor  

withdrawal. Do not block the pressure relief valve during 

use or storage.

•  The cylinder be disconnected when the appliance is not 

in use.

1)  Do not store a spare LP-gas cylinder under or near this 

appliance;

2)  Never fill the cylinder beyond 80 percent full; and
3)  If the instructions in “-b12(a)” and “-b12(b)” are not  

followed exactly, a fire causing deathor serious injury 

may occur.

 

5.5 Lighting instructions

1.  Read all instructions before lighting. 
2.  Open lid during lighting. 
3.  Make sure the gas control knob is in “OFF” position.
4.   Push the gas control knob and quickly turn counterclockwise to “HIGH”  

position. The igniter will click and light the burner.

5.   If ignition does not occur in 5 seconds, turn the gas control knob off, wait  

5 minutes, and repeat steps 2 - 5.

* Before cooking on this grill for the first time, operate the grill for about 15 minutes 

with the lid closed and the gas turned on “HIGH”. This will “heat clean” the internal 
parts and dissipate odor from the painted finish.

* Clean your grill after each use. DO NOT use abrasive or flammable cleaners,  

As it will damage the parts of this product and may start a fire. Clean with warm 
soapy water.

If the burner does not light, turn the gas control knob off and wait 5 minutes to let the gas clear before you try again. 
(please see the 5.3 Installing the gas cylinder)

5.2 Special Instructions for the Use of Regulator and Propane Cylinder

Содержание CGG-240 Assembly and

Страница 1: ...ppliance with 25 feet 7 5m of any flammable liquid 4 lf a fire should occur keep away from the appliance and immediately call your fire department Do not attempt to extinguish an oil or grease fire wi...

Страница 2: ...nstallation of this product must conform to local codes In the absence of local codes use the National Fuel Gas Code ANSI Z223 1 NFPA54 Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 o...

Страница 3: ...ad 23 M5X10 Screw 38 Left Handle Support 10 Right Handle Assembly 24 Wheel 39 M6 Nut 11 Regulator 25 Axle Bolt Hex Nut 40 Left Side Table 12 Gas Valve Assembly 26 Axle Bolt 41 Plastic Washer 13 Contro...

Страница 4: ...Screws Part N as shown Step 2 Wheel Assembly Attach Wheel Part G to Cart Leg Assembly Part J with Axle Bolt Part H and Axle Bolt Hex Nut Part I as shown Repeat for opposite side wheel Step 3 Leg Asse...

Страница 5: ...grill is in use Be certain that the side tables are locked into place as shown when placing items on the side tables The shelves slide inward for easy storage and transport when the grill is not in us...

Страница 6: ...y 4 Locate the grill away from any combustible and non combustible material or construction by at least 24 inches 61cm from back and 24 inches 61cm from side See the diagram below 5 Never store or use...

Страница 7: ...not in use 3 Do not store a spare LP gas cylinder under or near this appliance 4 Never fill the cylinder beyond 80 percent full and 5 If the instructions in b12 a and b12 b are not followed exactly a...

Страница 8: ...BURNER ELEMENT OR ATTEMPT TO CLEAN IN ANY WAY DO NOT USE WATER OR LIQUIDS TO CLEAN GRILL INTERIOR Replace flame tamer and securing screw CAUTION DO NOT OPERATE GRILL WITHOUT FLAME TAMER IN PLACE 7 Fre...

Страница 9: ...other Cuisinart Grilling products please visit us at www cuisinartgrilling com or call 1 800 211 9604 Model CGG 240 North American Distributor The Fulham Group Newton MA 02460 BURNER WON T LIGHT USIN...

Отзывы: