Wired Touch Panels
9
© CUE, a.s. | All Rights Reserved.
Part Description
Microphone
The microphone is prepared for future use. The functionality depends on a firmware version.
Proximity sensor
The Motion sensor resumes touch panel from Backlight Saver mode. This functionality can be enabled /
disabled using On Screen Display or Admin Web.
Light Sensor
The Light Sensor automatically adjusts display backlight according ambient light level. This function has
to be enabled using On Screen Display or Admin Web.
Touch-screen display
Touch-screen display with active matrix color LCD and resistive membrane touch overlay.
Speakers
The built-in stereo speakers allows to play sounds stored in the touch panels.
System Default Button
When pressed the factory default function is performed. For factory default values see chapter Factory
Default and System Default. A thin screwdriver is needed for press of this button.
Network Connector
The 10/100 BaseT LAN is a standard network connection equipped with Power over Ethernet using RJ-45
connector. For more details see chapter Connection.