background image

7

4. 

Charging a battery grounded to the positive terminal: Positive grounded vehicle 

Charger connection.

    1.  Connect negative charger clip (black) to negative battery terminal.

    2.  Connect positive charger clip (red)  to a good metal engine ground away from 

the battery. Do not connect clip to fuel lines or sheet-metal body parts. 

    3.  Connect the AC cord to the socket. The red alarm indication light will indicate a 

battery which is connected to reverse polarity.

Connecting the MULTI US 3300 to an out of vehicle battery: 

a) 

Check polarity of battery terminals. POSITIVE (POS, P, +) battery post usually has 

larger diameter than NEGATIVE (NEG, N, -) post.

b) 

Connect POSITIVE (RED) charger clip to POSITIVE (POS, P, +) battery post. 

c) 

Connect NEGATIVE (Black) charger clip to NEGATIVE (NEG, N, -) battery post. 

The red alarm indication light will indicate a battery, which is connected to reverse 

polarity.

d) 

Connect charger’s AC cord to socket. 

e) 

Do not face the battery when making the final connection.

f) 

When disconnecting charger, disconnect in reverse sequence from connecting 

procedure. See operating instructions for charge information.

Starting the charging process

1. 

Set the correct charge mode by pressing the mode button. You can find out how to 

select the correct charge mode to be used for charging your battery in the section on 

“SETTINGS”. 

2. 

Once you have established that the battery cable has been correctly connected you 

can start the charging process. To do so, insert the charger plug into the AC socket. 

3. 

Now either the charge indicator   or the maintenance charge indicator   lights 

up. When the maintenance charge indicator lights up, the battery is fully charged. If the 

battery voltage drops, the charger sends a pulse to the battery. The length of the pulse 

depends on how much charge the battery has lost. The MULTI US 3300 may be con-

nected for months at a time. However it is recommended to monitor batteries on charge.

4. 

If nothing happens: If the indicator for the set voltage is still illuminated, but no other 

indicator is illuminated, the connection to the battery or the chassis could be faulty, or the 

battery could be defective. If the charging process has not started, this could be due to 

the fact that the power socket is not supplying a current. 

5. 

The charging process can be interrupted at any time. In addition pull the plug of the 

charger out of the power socket or put the charger on Stand-by/Power On  . Always 

remove the plug of the charger from the power socket before disconnecting the battery 

cable. If you interrupt the charging process of a battery fitted in a vehicle, the battery 

cable must always be first disconnected from the chassis and then from the other battery 

cable.

Содержание MULTI US 3300

Страница 1: ...Switch Mode BATTERY CHARGER For lead acid batteries 2 90 Ah MULTI US 3300 User s Manual and a guide to professional battery charging For Starter Deep Cycle batteries US...

Страница 2: ...y to persons 5 To reduce risk of damage to electric plug and cord pull by the plug rather than by the cord when disconnecting charger 6 An extension cord should not be used unless absolutely necessary...

Страница 3: ...acts skin or clothing wash immediately with soap and water If acid enters eye immediately ood eye with running cold water for at least 10 minutes and get medical attention immediately e NEVER smoke or...

Страница 4: ...ne voltage of battery by referring to car owner s manual and make sure that the output voltage selector switch is set at correct voltage 14 CHARGER LOCATION a Locate charger as far away from the batte...

Страница 5: ...nnect negative charger clip black to negative battery terminal 2 Connect positive charger clip red to a good metal engine ground away from the battery Do no connect clip to fuel lines or sheet metal b...

Страница 6: ...eck whether the charger has been switched to maintenance charge before you leave it turned on or unobserved for any length of time Caution If the MULTI US 3300 does not switch to maintenance charge mo...

Страница 7: ...arge mode to be used for charging your battery in the section on SETTINGS 2 Once you have established that the battery cable has been correctly connected you can start the charging process To do so in...

Страница 8: ...ld however only be seen as guidelines Please consult the battery manufacturer for further instructions Settings are made by pressing the MODE button and stepping forward one press at a time until the...

Страница 9: ...s methods are used depending on the time of the measurement see table When Reading Yes No Before the start or after changing the charging mode Voltage higher than 12 9 V Green indicator lit until the...

Страница 10: ...state of charge The time for the Absorption should be added Battery size Ah Mode Time h 2 2 3 8 8 10 14 3 4 50 12 14 90 23 26 INDICATORS Incorrect polarity Charging process Charging completed Pulse m...

Страница 11: ...of batteries All types of lead acid batteries Battery Capacity 2 90 Ah Dimensions 6 1 2 x 2 3 8 x 1 1 2 inches L x W x H Enclosure Splashproof Rainproof Weight 1 1 lbs The back current drain is the cu...

Страница 12: ...anty to the original purchaser of this product This limited warranty is not trans ferable CTEK SWEDEN AB warrants this unit for two years from the date of purchase against defect workmanship or materi...

Отзывы: