e)   Do not face the battery when making the final connection.

f) 

 When disconnecting charger, disconnect in reverse sequence from connecting 

procedure. See operating instructions for charge information.

The battery charger must be connected to the battery according to the instructions 

above.  

IMPORTANT SAFETY INFORMATION!

The MULTI US 3300 cannot be used to restore a fully worn out battery.  

If the MULTI US 3300 does not switch to maintenance charge after three days (green light 

illuminated), there is a fault. Possible causes: 

•  

The battery is probably worn out and should be replaced. 

•  

Some large antimony batteries may behave different and can allow the MULTI US 3300 

to charge the battery for too long, which can lead to overcharging. See caution!

•  

If heavy power consumers like fitted alarms and navigation computers are connected to 

the battery, the charging process takes longer and this can also overcharge the battery. 

•  

A sulphated battery will only accept current with difficulty, and consequently the 

charging process takes a particularly long time. A worn out battery cannot be fully 

charged. Therefore you should always check whether the charger has been switched to 

maintenance charge before you leave it turned on or unobserved for any length of time. 

Caution: If the MULTI US 3300 does not switch to maintenance charge mode after three 

days, manually switch it to pulse maintenance mode. If the set has been switched to 

maintenance charge, then everything is in order. Note: A battery that hasn’t changed to 

maintenance charge after three days is most likely worn out and needs to be replaced. All 

other batteries can be maintained for a very long time.

CHARGING

Connecting the MULTI US 3300: 

- Connecting the equipment to a battery fitted in the vehicle

1. 

When the battery cable is being connected or disconnected, the plug of the  

MULTI US 3300 must be disconnected from the power socket.

2. 

Establish which terminal is ground (connected to the chassis). Normally the negative 

terminal is grounded.

3. 

Charging a battery grounded to the negative terminal: Negative-grounded vehicle

Charger connection.

    1.  Connect positive charger clip (red) to positive battery terminal.

    2.  Connect negative charger clip (black) to a good metal engine ground     

away from the battery. Do not connect clip to fuel lines or sheet-metal body parts. 

    3.  Connect the AC cord to the socket. The red alarm indication light will indicate a 

battery which is connected to reverse polarity.

Содержание MULTI US 3300

Страница 1: ...Switch Mode BATTERY CHARGER For lead acid batteries 2 90 Ah MULTI US 3300 User s Manual and a guide to professional battery charging For Starter Deep Cycle batteries US...

Страница 2: ...y to persons 5 To reduce risk of damage to electric plug and cord pull by the plug rather than by the cord when disconnecting charger 6 An extension cord should not be used unless absolutely necessary...

Страница 3: ...acts skin or clothing wash immediately with soap and water If acid enters eye immediately ood eye with running cold water for at least 10 minutes and get medical attention immediately e NEVER smoke or...

Страница 4: ...ne voltage of battery by referring to car owner s manual and make sure that the output voltage selector switch is set at correct voltage 14 CHARGER LOCATION a Locate charger as far away from the batte...

Страница 5: ...nnect negative charger clip black to negative battery terminal 2 Connect positive charger clip red to a good metal engine ground away from the battery Do no connect clip to fuel lines or sheet metal b...

Страница 6: ...eck whether the charger has been switched to maintenance charge before you leave it turned on or unobserved for any length of time Caution If the MULTI US 3300 does not switch to maintenance charge mo...

Страница 7: ...arge mode to be used for charging your battery in the section on SETTINGS 2 Once you have established that the battery cable has been correctly connected you can start the charging process To do so in...

Страница 8: ...ld however only be seen as guidelines Please consult the battery manufacturer for further instructions Settings are made by pressing the MODE button and stepping forward one press at a time until the...

Страница 9: ...s methods are used depending on the time of the measurement see table When Reading Yes No Before the start or after changing the charging mode Voltage higher than 12 9 V Green indicator lit until the...

Страница 10: ...state of charge The time for the Absorption should be added Battery size Ah Mode Time h 2 2 3 8 8 10 14 3 4 50 12 14 90 23 26 INDICATORS Incorrect polarity Charging process Charging completed Pulse m...

Страница 11: ...of batteries All types of lead acid batteries Battery Capacity 2 90 Ah Dimensions 6 1 2 x 2 3 8 x 1 1 2 inches L x W x H Enclosure Splashproof Rainproof Weight 1 1 lbs The back current drain is the cu...

Страница 12: ...anty to the original purchaser of this product This limited warranty is not trans ferable CTEK SWEDEN AB warrants this unit for two years from the date of purchase against defect workmanship or materi...

Отзывы: