Electrical:
The
DM200R
uses two NEMA 56 Frame, 2 H.P. 3 Phase, 3450 RPM, 60 Hertz TEFC Motors.
The
DM400
uses two NEMA 213T or 215T Frame, 8 H.P. 3 Phase, 1725 RPM, 60 Hertz TEFC Motors.
CTD uses a speed up so that the blades run at approximately 12,000 SFPM. Electrical installation should
be performed by a qualified and certified electrician. It is highly recommended that a lock-out or disconnect
switch be located close to the machine between your main electrical panel and the machine. This disconnect
switch is used to shut off power to the machine and should be used whenever the blades are changed, or at anytime
the machine is serviced and the blades are exposed.
A Magnetic Starter for each motor is supplied. This starter protects the motor from overheating and will not allow
the motor to restart itself after power outages or undervoltage situations.
Electrical Installation of Power to Starter by a Qualified Electrician:
All wiring from the motors to the starter has been completed and tested at the factory several times.The voltage
has been clearly tagged.
DO NOT CONNECT ANY VOLTAGE THAT IS
DIFFERENT
THAN
THE TAGGED VOLTAGE, AS THIS MAY CAUSE SEVERE DAMAGE AND DANGER.
Consult the factory if any
changes are needed.
Bring power lines to the top of each Magnetic Starter. Use dust-proof connectors if available.
Single Phase Motor Replacement:
Connect leads to L1 (line 1) and L2 for single phase motors. (See Wiring Diagram for Single Phase Motors
on Page No. 7.) Green ground wire must be grounded to enclosure. If using type “SO” wire and plug, use
a romex connector through starter box and a grounded plug.
Be sure to check rotation
. The blade must
rotate down and to the rear on the underside of the blade.
Three Phase Motor Replacement:
Connect incoming power line leads to L1 (line 1), L2 and L3. (See Wiring Diagram for Three Phase Motors
on Page No. 7.) Green ground wire must be grounded to enclosure.
Be sure to check rotation
as polarities may be
different. The blade must rotate down and to the rear on the underside of the blade. If a change in rotation is necessary,
reverse any two of the incoming power wires.
Example: If the blades are running backwards and incoming wires are
connected White L1, Black L2, Red L3, switch the
Black wire with the Red so that Black is connected to L3 and Red is connected to L2. This will change the motor
to rotate properly.
-6-
MOTOR LOAD AMPERES
Motor
Model
Frame
208 Volt
230 Volt
460 Volt
2 H.P. 3 Phase
DM200R
56Z
5.7 amps
5.4 amps
2.7 amps
2 H.P. 1 Phase
DM200R (optional)
56Z
N/A
12.5 amps
N/A
3 H.P. 3 Phase
DM200R (optional)
56Z
7.8 amps
7.4 amps
3.7 amps
8 H.P. 3 Phase
DM400
213T
21.5 amps
20 amps
10 amps
10 H.P. 3 Phase
DM400 (optional)
215T
28 amps
26 amps
13 amps
Содержание DM200R
Страница 18: ... 18 ...
Страница 19: ... 19 ...
Страница 20: ...DM200 Base Assembly Exploded View Right Side Shown Left Opposite 20 ...
Страница 21: ...DM200 Base Assembly Parts List 21 ...
Страница 22: ... 22 ...
Страница 23: ... 23 ...
Страница 24: ...400S Blade Guard and Stand Exploded View Model M516 Shown Right Side Shown Left Opposite 24 ...
Страница 25: ...400S Blade Guard and Stand Parts List Model M516 Shown 25 ...
Страница 26: ... 26 ...
Страница 27: ...400S Base Parts List Model M516 Shown 27 ...
Страница 28: ... 28 ...
Страница 29: ...Parts list 29 ...
Страница 30: ... 30 ...
Страница 35: ......