CTcoin Blackbird 3300 Скачать руководство пользователя страница 8

 

High speed coin counting operation instructions

 

The default batch quantities can be changed as   

following steps: 

·  Press both B key and M key, then turn on the   

power, the machine will enter into the “batch   
changing mode” and the display show “bAt- 
SEt”; 

 

  ·Press B key to select the default memorized   

default batch quantities which you want   
to change; 

 

 

 

·Change the selected default batch quantities   

by pressing any numeric key; Save the amended   
default batch quantities in the memory   
by pressing M key, the previous default   
batch quantities will be replaced; 

 

 

·Turn off the power and turn on again, check if the default batch quantities have been 

changed correctly. 

 

Reject small coins mixed 

 
Before putting the coins into the Hopper, please remove all paper scraps, lint, rubber bands, 
etc.,  which  may  be  mixed  with  the  coins.  Foreign  objects  may  cause  jamming  or  faulty 
counting. 
 

§

 

Set the Coin Diameter Adjusting Knob   

  and the Coin Thickness Adjusting Knob 
  according to the size of the coins to be 

counted. 

 

§

 

If a few small coins are

 

mixed with the coins,   

install the Coin Reject Box onto the side of the   
machine.   

 

Содержание Blackbird 3300

Страница 1: ...Coin Counter OPERATION INSTRUCTIONS Blackbird 3300 CTcoin A S Helsingborggade 9 DK 5100 Odense C Tel 45 6312 7550 Fax 45 6312 7551 www ctcoin com ctcoin ctcoin com 7519...

Страница 2: ...s Content 1 Introduction 3 2 Technical Specifications 4 3 Key Panel 4 4 Precautions 5 5 Operation Procedures 5 6 Reject small coins mixed 8 7 Set up the Coin Tube Holder 9 8 Troubleshooting 10 9 Daily...

Страница 3: ...this document Should you have any questions please contact local distributor or sales agent for further advice General Information 1 Diameter Adjusting Knob 2 Extender Hopper 3 Hopper 4 Thickness Adj...

Страница 4: ...ing Mode Power Consumption 70 W During operation Power Requirements AC 120V 10 60Hz or AC 220V 10 50Hz Dimension 270 w x 362 d x 240 h mm 10 63 w x 14 25 d x 9 45 h inches Net Weight 11 kg or 24 2 lbs...

Страница 5: ...on the floor or on a stand to prevent the machine from tipping over Operation Procedures If you have a large quantity of coins to be counted install the Extended Hopper supplied as right diagram If yo...

Страница 6: ...ey Counting will begin The machine will stop automatically reverse for 1 second and continue counting in following conditions There are objects jamming in the passage which caused the counting sensor...

Страница 7: ...unting will be accumulated from the previous number on the display Batch Mode First way Press any numeric key the BAT indicator on the right side of the display will be on to input your desired random...

Страница 8: ...tch quantities in the memory by pressing M key the previous default batch quantities will be replaced Turn off the power and turn on again check if the default batch quantities have been changed corre...

Страница 9: ...t Box or the Reject Coin bag If there are bigger coins mixed with coins to be counted the bigger coins possibly jam in the inlet of the coin passage and cause the reverse or abnormal stop in that case...

Страница 10: ...ach paper tube set the batch number in batch counting mode then start counting The machine will stop when the count total reaches the batch quantity All the counted coins will drop into the Paper Tube...

Страница 11: ...covered by dust the LED will display JA please remove the V Belt clean the counting sensor using a cotton stick with denatured alcohol Daily Maintenance Be sure to turn the main power off before attem...

Страница 12: ...Rear Feed Pulley can be adjusted by adjusting the position of the screwk Then tighten the nutj nutk nutl Remove the Rubber Washer on the Plastic Pedal unscrew the four screws in the Plastic Pedal Uns...