background image

S E C T I O N   2 :   I N S T A L L A T I O N  

 

 

M N X 1 0 0 0 1 ,   R E V   C  

  2 / 8 / 2 0 1 2  

8  

 

Connection Technology Center, Inc. 

 7939 Rae Boulevard 

 Victor, NY 14564 

 (585) 924-5900 

 

 
 
 

 

SIGNAL OUTPUT ±

 is an unfiltered connection showing the raw signal from the 

transducer. 
 

BNC SIGNAL OUT

 serves the same function as the SIGNAL OUTPUT ± 

connection. 
 

ANALOG OUTPUT ±

 is the filtered connection with a 4-20 mA signal 

proportional to full scale output. 

 

Figure 3 - Front Panel 

Analog Output 

Zero 

Adjustment 

Содержание Pro SC901 Series

Страница 1: ...M N X 1 0 0 0 1 R E V C 2 8 2 0 1 2 1 ConnectionTechnologyCenter Inc 7939RaeBoulevard Victor NY14564 585 924 5900 SC901 Series Hazardous Area Factory Set Vibration Signal Conditioners...

Страница 2: ...W 4 Introduction 4 Product Selection Guide 5 Specifications 6 Environmental 6 Electrical 6 Physical 6 SECTION 2 INSTALLATION 7 Description 7 Mounting Instructions 8 Electrical Connections 8 SECTION 3...

Страница 3: ...S M N X 1 0 0 0 1 R E V C 2 8 2 0 1 2 3 ConnectionTechnologyCenter Inc 7939RaeBoulevard Victor NY14564 585 924 5900 Figure 1 SC901 Series Selection Guide 4 Figure 2 Mounting Dimensions 8 Figure 3 Fro...

Страница 4: ...ument contains information on the operation installation and maintenance of the SC901 Series Signal conditioner for Hazardous Areas The SC901 Series signal conditioner accepts input from an accelerome...

Страница 5: ...range 0 95 Relative Non Condensing Electrical Power 20 32 VDC unregulated 8 pole low pass and high pass Filter Filter roll off is better than 42 dB octave Accepts mV Input Filters the signal Normaliz...

Страница 6: ...l connectors WAGO 237 series positive force terminal blocks for the signal output and sensor input There is also a green indicator light Sensor OK which illuminates when the transducer is properly con...

Страница 7: ...nsions Electrical Connections 1 Connect the 24 VDC input power to the two connectors 24 VDC INPUT on the top front of the signal conditioner 2 Connect the cables from the transducer to the SENSOR INPU...

Страница 8: ...tor NY14564 585 924 5900 SIGNAL OUTPUT is an unfiltered connection showing the raw signal from the transducer BNC SIGNAL OUT serves the same function as the SIGNAL OUTPUT connection ANALOG OUTPUT is t...

Страница 9: ...upplies constant current power turn the power supply off in the data collector prior to collecting data Analog Output Zero Adjustment This section contains test setup and procedures for adjusting the...

Страница 10: ...onnectionTechnologyCenter Inc 7939RaeBoulevard Victor NY14564 585 924 5900 Common Problems Blinking green sensor OK light indicates that sensor is not attached Check sensor and cable connections Note...

Страница 11: ...required Basic visual checks to ensure integrity should be made periodically General There are no customer replaceable parts The product has been designed for trouble free service under normal operati...

Отзывы: