12 

 

Bypass Relay Function for ITP-800(-E) 

     ITP-800(-E)  provides  two  copper  interfaces  with  auto  bypass  relay 
function in the event of sudden power loss particularly in daisy chain or 
linear  topology.  When  power  failure  occurs  in  one  of  the  switches, 
bypass  relay  function  can  activate  bypassing  mechanism  by 
interconnecting  internal  circuits  automatically  to  ensure  that  links 
between switches operate uninterruptedly and continuously. 
 

 

Normal State 

 

 

 

 

 

 
 
 
 
 
 
 
 

 

 

 

 

 

Bypass Relay Function Activated 

Figure 10:  Bypass Relay Function Illustration 

Failure 

Power 

on 

Power 

on 

Power 

on 

 

Power 

on 

Power 

on 

Power 

on 

Power 

on 

Содержание ITP-500

Страница 1: ...1 Quick Installation Guide sales ctcu com ITP 500 E ITP 800 E IP56 5 x 10 100Base M12 Hardened IP56 8 x 10 100Base M12 Hardened...

Страница 2: ...heir respective owners Technical information in this document is subject to change without notice CTC Union Technologies Co Ltd Far Eastern Vienna Technology Center Neihu Technology Park 8F No 60 Zhou...

Страница 3: ...application the Buyer shall indemnify and hold CTC Union Technologies and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages expenses and reason...

Страница 4: ...CHANICAL 6 ENVIRONMENTAL 7 CERTIFICATIONS 7 MTBF MIL HDBK 217 7 Panels 8 PIN Assignment 9 M12 ETHERNET CABLE 9 M12 POWER INPUT CABLE 9 M12 Cable Connector Installation 10 Bypass Relay Function for ITP...

Страница 5: ...with EN 50155 standard that covers strict demands on operating temperature power input voltage surge ESD vibration and shock thus making these switches suitable for industrial applications such as veh...

Страница 6: ...8 100 ohm 100m Power Connector Type 5 Pin Male A Code M12 Power Supply ITP 500 E DC 12 24 48V 8 4 60VDC input power ITP 800 E Redundant Dual DC 12 24 48V 8 4 60VDC input power Support Power Input Reve...

Страница 7: ...for Heavy Industrial Environment EN61000 6 4 EMS Electromagnetic Susceptibility Protection Level EN61000 4 2 ESD Level 3 Criteria B EN61000 4 3 RS Level 3 Criteria A EN61000 4 4 Burst Level 3 Criteri...

Страница 8: ...net port LED 8 Ethernet port label 9 Two Bypass ports ITP 800 only 10 Power port pin assignment table 11 Ethernet port pin assignment table 12 Compliant standards Table 1 Panel Reference Table Figure...

Страница 9: ...tive 2 Blue N C No Connection V2 Power Supply 2 Positive 3 Red V Power Supply Negative V1 Power Supply 1 Negative 4 Orange N C No Connection V2 Power Supply 2 Negative 5 Yellow Grounding Grounding Mal...

Страница 10: ...t the screw nut O ring and housing into the cable in the order shown in Figure 2 and keep them loose in this step Step 2 Strip the cable and the individual cores to fit the connector Insert the stripp...

Страница 11: ...11 Step 3 Tighten the connector in clockwise direction making sure that the wires inside the connector are not twisted as the screwed housing is assembled Figure 9 Tighten the Connector...

Страница 12: ...hen power failure occurs in one of the switches bypass relay function can activate bypassing mechanism by interconnecting internal circuits automatically to ensure that links between switches operate...

Страница 13: ...steps below to install ground wire Step 1 Prepare one suitable ground screw and one grounding cable Step 2 Attach the grounding screw to the ring terminal of the grounding cable Make sure that the gr...

Страница 14: ...le and easy and only requires to prepare two appropriate wall screws for mounting the Ethernet Switch After you find a suitable place to wall mount the Ethernet Switch remember to align the mounting h...

Страница 15: ...15 Application Figure 12 On board Train Application Diagram NOTES...

Страница 16: ...16 Version Date Description 1 4 2020 3 31 Use new document format Revise spec...

Отзывы: