Connectors
LAN and Fiber Connection
IFS-402GSM-4PH(E)24 PoE switches have 4 electrical LAN ports
(labeled 1
~
4) and 2 fiber ports (SFP based, labeled Fiber 5
~
6) on the
front panel. The LAN ports that utilize shielded RJ-45 connectors support
10/100M; while the fiber SFP ports support 100/1000M.
PoE Ports
All 4 LAN ports support PoE (Power over Ethernet) per IEEE802.3af
(15.4W) or IEEE802.3at (30W) for connection to standard PoE PD (Power
Devices) such as IP Cameras, Access Points, IP Phones, Digital Signage,
etc. PoE eliminates the need to run separate power to these devices
thereby simplifying deployment and reducing expenses.
The LAN ports may also connect to any non-PoE device for normal
Ethernet transmission without any damage to the non-PoE device or to
this device.
RJ-45 Ethernet Port Pinouts
Figure 2. RJ-45 Ethernet Port Pinouts
RJ-45 Ethernet & PoE Pin Assignments
Pin
No.
RJ-45 Ethernet
100Base-TX
PoE Output
1
RX+
V+
2
RX-
V+
3
TX+
V-
4
-
5
-
6
TX-
V-
7
-
8
-
Power and Alarm
Figure 5. Terminal Block
A removable terminal block on the top panel provides both power
and alarm connections. Power can be provided through the dual inputs
from separate sources. The alarm relay contact can be wired into an
alarm circuit which senses an alarm condition when the contact is
broken. The alarm relay is normally closed when there is no alarm
condition. The alarm conditions are user programmable through
management to include power, link faults or other fault conditions.
Please note that the alarm relay contact can only support 1A current at
24VDC. Do not apply voltage and current that exceed these
specifications.
CLI & Web Basic Operation
IFS-402GSM-4PH(E)24 are managed Fast Ethernet PoE switch devices.
Initial configuration (assignment of IP address) may be accomplished via
the RS-232 console and a PC or laptop running terminal emulation
software. Configure the terminal as follows:
115200 speed, 8 data bits, no parity, 1 stop bit, no flow control
IFS-402GSM-4PH(E)24 PoE switches use a command line interface (CLI)
through the serial port. Once the IP address has been configured, a web
browser can be used to configure the device through a more easy to use
GUI (graphical user interface). Please refer to the operation manual on
the CDROM.
Using the provided console cable, connect the RJ-45 to the
"CONSOLE" port and the DB9 to PC COM port. Apply power to the switch.
At the "Username:" prompt, enter '
admin
' (lower case, no quotes). Just
press Enter when prompted for password
.
To set the IP address and subnet mask issue this command:
> ip address 1 192.168.0.250/24
(example: sets VID 1 to 192.168.0.250, subnet 255.255.255.0)
NOTE: The factory default IP address is 10.1.1.1 with mask
255.255.255.0
CONSOLE Port
The RJ-45 port labeled “CONSOLE” is an RS-232 terminal port for local
management. These models use a “light” CLI (Command Line Interface)
in addition to a user friendly Web interface and industry standard SNMP.
See page 5 for basic CLI and Web operation.
One RJ-45 to DB-9 cable is provided with this device. CONSOLE port
pinouts (Figure 2) and RS-232 DB-9 (Figure 3) connector are illustrated
below together with RJ-45 to DB-9 signal mapping information. Use the
supplied cable to connect the RJ-45 CONSOLE port to a console PC.
Figure 3. CONSOLE Port Pinout
Figure 4. RS-232 (Female) Pinout
RJ-45 to DB-9 Signal Mapping
DB-9 (Female)
Direction
RJ-45
Signal
Pin
Pin
Signal
RXD
2
3
TXD
TXD
3
6
RXD
GND
5
5
GND
LED Indicators
LED
Color
Definition
PWR1/
PWR2
Green
Power is connected and active at the
PWR1/PWR2 input terminal connection.
Off
PWR1/PWR2 is not connected.
Fault
Amber
When one or more of the programmable
alarm conditions is active.
Off
Normal operation without faults.
Alarm conditions are all disabled.
CPU ACT
Green
Lit during normal use, indicating a healthy
condition of the running CPU.
Ring
Master
Yellow
Lit when this unit is the 'master' in a ring
and all units are configured for u-Ring or
ERPS.
LAN
LINK/ACT
Green
Ethernet link is up.
Blinking
Blinking when there is Ethernet traffic.
Off
No Ethernet link.
10/100
Green
The connected LAN speed is 10/100M.
Off
No Ethernet link.
FIBER
LINK/ACT
Green
The fiber SFP link is up.
Blinking
Blinking when there is data traffic.
Off
No fiber link.
PoE
Green
The respective LAN port has successfully
negotiated PoE and is supplying output
power to the remote connected PD.
Blinking
One of the PoE faults (overload, short
circuit, port failure at startup) occurs.
Off
PD is not connected or output power is not
provided.
Application
- 4 -
- 6 -
Figure 7. u-Ring Topology and Application
Figure 1. IFS-402GSM-4PH(E)24 Front Panel
- 5 -
- 3 -
Fault
Figure 6. Alarm Relay Circuit
Normally Closed (NC)
www.ctcu.com