Chapter 4. Operation
4-13
Version 1.0b Mar 2003
<<< FMUX UNIT SYSTEM STATUS >>> 11:27:24
PORT 1 PORT 2 PORT 3 PORT 4 Optic PWR
| 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D O1 O2 P1 P2
--- LOCAL --------+------------+-----------+-----------+-----------+-----+------
Service Status | v v v v | | | |v S |v
Loss of Signal | | | | | |
Loopback Status | | | | | |
Major Alarm | | | | | |
Minor Alarm | | | | | |
| 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D O1 O2 P1 P2
--- REMOTE -------+------------+-----------+-----------+-----------+-----+------
Service Status | v v v v | | | |v S |v
Loss of Signal | | | | | |
Loopback Status | | | | | |
Major Alarm | | | | | |
Minor Alarm | | | | | |
------------------+------------+-----------+-----------+-----------+-----+------
PORT 1 PORT 2 PORT 3 PORT 4 Optic PWR
[v]In Service [*]LOS [o]Loopback [a]minor [A]major [S]Standby
Press <ESC> key to Exit.
The System Status display gives a overview of the entire system, both local and remote unit, the
channel conditions, optical connections, and power supply status. In the above display note that
only a Port 1 card is installed and that all 4 channels (1A~1B) are in service (v) without any errors
from local or remote side. The optical 1 (O1) connection is in service (v) and optical 2 (O2) is in
standby (S) mode. Only one power supply (P1) is active in both local and remote side units.
The display screen will refresh every 5 seconds. Of course if the optical link is completely lost then
no status information will be available from the remote side, all fields will go blank, and the refresh
will take more than 20 seconds.
Another important diagnostic display of the FMUX is the Alarm Buffer display. Note that it is item
three on the root menu. If we press "3" the Alarm Buffer will display.
LOCAL
<<< Alarm Buffer Display >>>
Channel Alarm Type ON/OFF DATE TIME
Terminal Local Logout 2002/11/01 11:10:04
Terminal Remote Login 2002/11/01 11:10:12
Optical Loopback ON 2002/11/01 11:12:22
Optical Loopback OFF 2002/11/01 11:12:33
Port 1-Ch D Loopback ON 2002/11/01 11:13:45
Port 1-Ch D Loopback OFF 2002/11/01 11:14:08
Terminal Local Logout 2002/11/01 11:22:55
Terminal Local Login 2002/11/01 11:23:55
Terminal Local Logout 2002/11/01 11:30:52
Terminal Local Login 2002/11/01 11:32:56
End of Alarm History
Press <ESC> key to Exit. or Press <C> to Clear Alarm Buffer.