CTC EcoEl
End user information
18
Menu Operation data
(the menu is directly accessed from the
main menu)
This menu displays current product and system temperatures and operating data.
Values in brackets are either required values or automatically generated values
which the product aims to achieve (expected values).
Outdoor °C
-5
Displays current outdoor temperature.
The product uses this value to determine a number of different operating data.
Boiler°C
47 (56)
Displays the upper boiler section temperature (electric boiler) and the temperature
which the boiler aims to achieve. This value automatically increases if a poor radiator
system requires higher temperatures.
Primfl °C
47 (49)
Displays the temperature of the water supplied to the house’s radiators, and the
temperature which the system aims to achieve. This value will vary during operation
depending on set parameters and current outdoor temperatures.
Boiler lower °C 48 (50)
Displays the lower boiler section temperature (electric boiler) and the temperature
which the boiler aims to achieve.
Heatingcir.pump
Displays the heating circuit (radiator) pump’s operating status. The pump stops in
On/Off
the summer time when there is no heating requirement. The pump is however
exercised occasionally to avoid it jamming.
El power
kW 6.0
Displays auxiliary power of the electric boiler (0…9 kW).
The electric boiler connects power in steps of 1.5 kW (6 connection steps).
Current
A 11 (20)
Displays the house’s total current consumption on the hardest loaded phase. The
house’s main fuse size is displayed in brackets. Assumes that the current sensor
upplied has been fitted to the incoming cables. If the current drawn exceeds the
main fuse size, the electric boiler automatically steps down a power step to protect
the fuses, for example when several high consumption equipment units in the house
are being used.
Mixing valve
A micro switch in the mixing valve valve’s motor ensures that auxiliary heating is not
used unnecessarily.
Program ID
Control program identity.
Program date
Control program version date.
Operation data
Outdoor °C
-5
Boiler °C
44 (56)
Primfl °C
47 (49)
Boiler lower °C
48 (50)
Heatingcir. pump
On/Off
El power kW
0.0
Current A
11 (20)
Mixing valve
Program ID
Program date