12
CTC Hot Water Storage Tanks
3. Removing and fi tting
insulation
These instructions apply to the following hot water storage tank models:
2.
4.
3.
1.
• CTC Hot Water Storage Tank 1. 500/50 (6 bar)
• CTC Hot Water Storage Tank 1. 750/50
• CTC Hot Water Storage Tank 1. 750/75
• CTC Hot Water Storage Tank 2. 750
It takes 2 people to remove and fi t the insulation.
Removal
1. Remove the cover trays (1) around the sleeves.
2. Release the clamps (2) on the back of the tank, carefully open the
hook-and-loop fasteners. Remove the clamp from the hook upside
down.
3. Hold the panel (3) and go around the tank in each direction, making
sure that the insulation comes off properly and is not snagged around
the sleeves. Carefully lay it down with the insulation facing upwards.
4. Remove the top panel (4).
Fitting
1. Fit the top panel.
2. Lift up the panel carefully and go around the tank. While one person
holds the panel on the back of the tank, the other person goes to the
front and gently pushes the insulation panel over the sleeves.
3. Attach the clamp to the hook upside down, but do not fasten yet. Start
from the front in the middle of the tank and go in each direction, while
pressing the insulation against the tank so that the hook-and-loop
fasteners attach to each other. Press the strip to the top panel. Start at
the front and work your way around. Tap lightly with a plastic hammer
so that the panel fi ts correctly into the strip’s groove.
4. Tighten the buckle, make sure that the strip is straight and does not
twisted, then tighten the lower one in the same way.
5. Refi t the cover washers.