CTB F4420125 Скачать руководство пользователя страница 12

The feed in the trough must always be sufficiently moist to enable the trough 
sensor to work. 

Initially, the feed presented should not be too liquid, but should be moist and 
crumbly. 

If the animals are fed by a wet/dry feeder after rearing, make sure that the 
water content of the feed in the trough is increased slowly to accustom the 
animals to liquid feed. This is not so critical when animals in a fattening house 
are fed by a liquid feed dispenser. 

Do not use acidic water! Acidic water can damage the standard water valve. 

The feed, which can be in the form of pellets, granular feed or meal, is poured into 
the feed funnel. During feeding, the crescent-shaped dispenser, operated by the 
drive motor, releases feed. The feed is conveyed outwards, past the platform rim 
over the entire surface and is equally distributed over the round trough. With every 
revolution of the crescent-shaped dispenser, a preset amount of water is measured 
out, controlled by a computer, onto the feed in the trough, via the water ring. 
Dispensing stops as soon as the dosing time is finished. 

Switch on/off the Rondomat 3S 

To switch the Rondomat 3S on / off press and hold (for 3 sec.) both the 

Feed plus 

button

 and 

Feed minus button

. When the Rondomat 3S is switched off, the 

Trough 

sensor LED

 lights up red. The status is also maintained in the event of a power 

failure. 

Set water amount 

The amount of water measured out per dispensing action is shown in the 

Water 

setting display

. In principle, water is always dispensed for as long as feed is 

dispensed, plus or minus the preset deviation in seconds (value range: -3 to 60). 

Press the 

Water minus button

 to reduce the amount of water by up to three

seconds.

Press the 

Water plus button

 to increase the water dispensing time in steps of one

second.

Water pressure approx. 2 bar: set the water amount to 0. 

Water pressure less than 1.5 bar: set a value in the range 1 to 3. 

Water pressure more than 2.5 bar: set a value in the range -1 to -3. 

Slowly increase the amount of water during the rearing process. 

Содержание F4420125

Страница 1: ...REVISED SEPTEMBER 2018 STU0001 F4420125...

Страница 2: ...ged products or goods costs of transportation lost sales lost orders lost income increased overhead labor and incidental costs and operational inefficiencies Some jurisdictions prohibit limitations on...

Страница 3: ...ded use 3 2 Introduction 4 2 1 Parts of the Rondomat 3S 4 2 2 Parts of the control unit 5 3 Place and mount the Rondomat 3S 6 4 Using the Rondomat 3S 7 4 1 Control options 7 4 2 Configure the Rondomat...

Страница 4: ...and additional information Warning indicating damage to the product if you do not follow procedures carefully Warning indicating danger to humans or animals Electrical shock hazard Danger to humans a...

Страница 5: ...ake precautions against electrostatic discharge ESD when working on the Rondomat 3S Ensure the workplace is clean and dry Use correct wires as shown in the connection diagrams Make all wiring connecti...

Страница 6: ...domat 3S has been developed specifically for the feeding of piglets must be installed and connected in keeping with the Assembly Instructions Only then is its safe operation possible and only then wil...

Страница 7: ...uction experience are Optimum reliability and optimum possibilities for monitoring and maintenance by personnel Rapid and easy replacement of worn parts Amply spaced access openings enabling easy thor...

Страница 8: ...ve and the moisture sensor are located at the bottom A fuse holder for primary and secondary voltage is installed on the power supply unit 1 Power supply connection 2 Dosing motor connection 3 Water v...

Страница 9: ...e mounted legs in the floor grid It is recommended to place the Rondomat 3S in the center of the house so the piglets have sufficient space around the Rondomat 3S Mount the feed and water lines 1 Feed...

Страница 10: ...S It consists of a water resistant impact proof front with input buttons indicators and text displays 1 Water setting display 2 Water plus button 3 Water minus button 4 Feed setting display 5 Feed plu...

Страница 11: ...ity value range 1 to 99 Lower values increase the sensor sensitivity whereas higher values decrease its sensitivity Option 3 Set the factory settings Restore the default values see below by pressing a...

Страница 12: ...amount of water is measured out controlled by a computer onto the feed in the trough via the water ring Dispensing stops as soon as the dosing time is finished Switch on off the Rondomat 3S To switch...

Страница 13: ...lding the Water plus button The water valve is opened for as long as the button is pressed and held Feed and water can be dispensed manually by pressing and holding the Feed plus button The water valv...

Страница 14: ...ainless steel and polymer concrete To clean the device remove the feed funnel to make all sections accessible After cleaning any water left behind in the trough can be drained by unscrewing the cleani...

Страница 15: ...at 24V 1 6A medium acting Water pressure 1 3 bar Housing Trough diameter 900 mm Height 1700 mm Weight unpackeged 94 kg Storing spare parts The spare parts must be stored in a frost free and dry locati...

Страница 16: ...13 Connect the power supply 1 Power adaptor 2 230V connector 3 24 V power supply Connect the ground cable 1 Ground cable...

Страница 17: ...blished English version of the manual For current product installation and operation information please contact the customer service and or technical service departments of the appropriate CTB subsidi...

Отзывы: