10
| English
2 610 A12 214 • 22.7.09
Work Examples
Sighting Out a Reference Height
At the beginning of your work, mark a reference height
at a suitable distance (furthest possible) on a stable
surface (e.g. on a tree or building), which you can use
as your reference point.
While working, periodically check the working height
to ensure that it has not changed with respect to the
reference height.
Projecting/Checking Heights
Place the measuring tool in horizontal position on a
firm surface or mount it to a tripod (accessory).
Working with expandable tripod: Align the laser
beam to the requested height. Project or check the
height at the target location.
Working without tripod: Determine the height differ-
ence between the laser beam and the height at the
reference point with the laser target plate
24
. Project
or check the measured height difference at the target
location.
Indicating a Plumb Line/Vertical Plane
To indicate a plumb line or a vertical plane, set up the
measuring tool in the vertical position. When the ver-
tical plane is supposed to run at a right angle to a ref-
erence line (e.g. a wall), then align the plumb beam
1
with this reference line.
The plumb line is indicated by the variable laser
beam
10
.
Troubleshooting
–
Causes and
Corrective Measures
When the corrective measures do not eliminate an
error, please contact an authorised service agent for
Bosch power tools.
Maintenance and Service
Maintenance and Cleaning
Store and transport the measuring tool only in the sup-
plied case.
Keep the measuring tool clean at all times.
Do not immerse the measuring tool in water or other
fluids.
Wipe off debris using a moist and soft cloth. Do not
use any cleaning agents or solvents.
Regularly clean the surfaces at the exit opening of the
laser in particular, and pay attention to any fluff of
fibres.
Note:
Before storing, allow the measuring tool and the
case to dry completely. Otherwise, vapours can deve-
lope in the closed case due to residual moisture, lead-
ing to corrosion of the measuring tool's circuit board.
In this case, warranty claims shall be rendered void.
If the measuring tool should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by an authorised after-sales
service centre for Bosch power tools. Do not open the
measuring tool yourself.
In all correspondence and spare parts orders, please
always include the 10-digit article number given on
the type plate of the measuring tool.
Cause
Corrective Measure
Measuring tool does not switch on or reacts
incorrectly
Batteries/rechargeable
batteries dead or defec-
tive
Check batteries/recharge-
able batteries with battery
tester and replace as
required, or charge
rechargeable batteries
Batteries/rechargeable
batteries incorrectly
inserted (wrong polarity)
Properly insert batteries/
rechargeable batteries
Battery contacts dam-
aged from leaky batteries/
rechargeable batteries
Clean battery contacts
Safety strip in battery
compartment not or not
completely removed
before starting operation
for the first time
Remove paper or paper
remainders between the
battery contacts
Measuring tool reacts implausible after press-
ing a button
For a reset of the soft-
ware, remove battery lid
22
and then mount again
Cause
Corrective Measure
OBJ_BUCH-1045-001.book Page 10 Wednesday, July 22, 2009 10:40 AM
Содержание Berger Lasermark Wizard LM30
Страница 1: ...en Original instructions Manual Horizontal Vertical Rotary Laser LM30 LM30...
Страница 2: ...2 2 610 A12 214 22 7 09 LM30 1 2 10 8 9 6 5 20 7 2 4 5 3 22 19 16 17 18 14 15 13 12 11 21...
Страница 3: ...3 2 610 A12 214 22 7 09 23 25 24 26 27 C A B...
Страница 4: ...4 2 610 A12 214 22 7 09 29 28 30 31 32 33 34 RC30...