D) Using the adjusting pin
provided in the case, turn the
reticle adjusting screws until
half the displacement has
been removed. Loosen one
screw 1/4 turn, then tighten
the opposing screw 1/4 turn.
E) Repeat steps A through D
until there is no displacement
of the target when the
instrument is turned about its
vertical axis.
Setting The Vertical Zero Position
16 • DGT2 - DGT10
PROCEDURE
KEY
DISPLAY
Accurately level the instrument
N/A
Press and hold the V% key while pressing
the power key. The instrument display will
enter the vertical zero adjustment mode.
Turn the telescope past the zero point.
The display will show "STEP 1".
Sight the telescope at a target that is level
with the instrument within 10 seconds.
Press "V%". This will store the data for the
first point. The display will show "STEP 2".
Reverse the telescope and re-sight the
original target. Press the "V%" key. This will
store the data for the second point and
establish a vertical zero point at level. Once a
key is pressed, the instrument will beep and
return to regular measurement mode.
V%
2X
V%
V%
V
O S E
L
V
H
R
S E - - 1
L
9 5 1 0 2 0
V
H
R
S E - - 2
L
9 5 1 0 2 0
V
2 6 1 1 2 4 3
H
R
1 8 0 0 0 0 0
Содержание 56-DGT10
Страница 2: ...1 3 4 5 7 2 6 8 9 10 FIG 1 11 12 13 14 15 16 17 18 19 20 2 DGT2 DGT10...
Страница 3: ...DGT2 DGT10 3 FIG 2 FIG 3 FIG 4 FIG 5 FIG 6 FIG 7...
Страница 5: ...DGT2 DGT10 5 Full Power Partial Power Low Power No Power FIG 15 FIG 16 FIG 17 FIG 18 FIG 19 FIG 20...
Страница 91: ...DGT2 DGT10 91 FIG 21 FIG 22 FIG 23 FIG 24 FIG 25 FIG 26 FIG 27 FIG 29 FIG 28...