SPECIFICATIONS

Product Number

CS1520

Applicable Standards

Type A, Security Grade 2, Environmental Class 2

AC Input Voltage

230v +10% -15%, 50Hz ± 15%

Output Voltage

13.7v ± 0.1V

Output Ripple

< 50mV (0.4% @ 13.6V)

Rated Output

See Rated Output table

APS Battery Type

1 x 7Ah or 1 x 8Ah lead acid gel

APS Recharge

<24 hours

Operating temp

-10

o

C to +4

o

C

Case Size

265 x 320 x 100mm

Weight

3.2 Kg

SUPPORT

For more information on this and other products please contact CSL Technical Support:

 

UK Tel:   

+44 (0)1895 474 444 

 

Ireland Tel:  

1800 855 695

 Email: 

 [email protected]

 

Hours: 

 

08.30 to 18.00 weekdays, 10.00 to 16.00 Saturday

Visit www.csl-group.com for the latest copies of all manuals.

© Copyright CSL Group

CSL1826V1 05112019

PD001826-001

Содержание CS1520

Страница 1: ...QUICK GUIDE INSTRUCTION MANUAL Grade 2 Boxed Power Supply 0 5 Amp ...

Страница 2: ...we give you the right tools for maximum support and minimum hassle It s service that s built around you csl group com installer INSTALLING CONFIDENCE 24 7 HELP DESK LIVE CHAT TRAINING VIDEOS COVERAGE MAPS APPS ...

Страница 3: ...onnect the 0V tamper and fault outputs to the control panel as appropriate see control panel manual for details Connect the 12V power output to the system Ensure that the tamper switch is connected to the PCB Fit the battery Switch on the AC supply and confirm that the EPS and APS LEDs are on 1 2 3 4 5 6 7 12V BAT 1 L E N A T PSU FLT PSU FLT EPS FLT TAMP AC FUSE TAMPER CONNECTOR AC SUPPLY CONNECTO...

Страница 4: ...uxiliary Power Supply APS fault Both Relay contacts open and all LEDs out total power down 12V POWER OUTPUT Terminal blocks are provided to connect to the system The Rated Output current is the maximum that can be drawn from the PSU s Power Output terminals This is shown in the Rated Output section The 12V OK LED indicates that 12V is available from these terminal blocks AUXILLARY POWER SUPPLY APS...

Страница 5: ...tation to determine typical expected battery life with a view to periodic replacement of the battery PSU RATING Power supplies conforming to the new European Standards ENs are specified differently from older designs The Rated Output current is the maximum that can be drawn from the PSU a With a mains supply and a flat standby battery that is being recharged and b With no mains supply battery only...

Страница 6: ...or 1 x 8Ah lead acid gel APS Recharge 24 hours Operating temp 10 o C to 4 o C Case Size 265 x 320 x 100mm Weight 3 2 Kg SUPPORT For more information on this and other products please contact CSL Technical Support UK Tel 44 0 1895 474 444 Ireland Tel 1800 855 695 Email support csl group com Hours 08 30 to 18 00 weekdays 10 00 to 16 00 Saturday Visit www csl group com for the latest copies of all ma...

Отзывы: