This product is suitable for use in systems designed to comply with PD6662:2010, EN50131-6
Grade 2 and Environmental Class 2. It is a Type A power supply. Rated Output = 0.5 Amp
INSTALLATION
Mount the metal enclosure onto the wall.
Connect the Live, Neutral and Earth terminals to the un-switched fused spur.
Connect the 0V, tamper and fault outputs to the control panel as appropriate (see control panel
manual for details).
Connect the 12V power output to the system.
Ensure that the tamper switch is connected to the PCB.
Fit the battery.
Switch on the AC supply and confirm that the ‘EPS’ and ‘APS’ LEDs are on
.