CSI UTP15-S2 Скачать руководство пользователя страница 14

 

 

SIGNATURE 2 SERIES 

           Valve Body Assembly

2

9

18

1

3

6

4

8

10

12

13

11

14

15

16

5

20

17

19

14

19A

7

6A

12A

Ref 

#

Description

Part #

Qty.

1

Piston Assembly

20001X231

1

2

10-24 X 13/16” Screw

20001X226

3

3

Seal and Spacer Kit Incl (5) #3 
& (4) #4

20561X253

1

4

End Spacer

N/S

1

5

Flow Control Button 5.0 GPM

20251X272

1

Flow Control Button 6.0 GPM

20251X274

1

Flow Control Button 7.0 GPM

20251X274

1

6

Plastic Flow Control Housing

20251X100

1

6A

Flow Control Assembly-Specify GPM 
Incl. (1) each #5, #6, #7
Flow Control Assy. 5.0 GPM-
PVC

20251X262

1

Flow Control Assy. 6.0 GPM-
PVC

20251X263

1

Flow Control Assy. 7.0 GPM-
PVC

20251X264

1

7

Drain Flow Fitting 90 º Elbow 
1/2” NPT X 1/2”

20251X255

1

8

Drain Retainer

20001X214

1

9

O Ring & Brine Valve Cap 
Assembly

20001X230

1

 10

O Ring & Filter Plug Assembly

20001X229

1

 11

10-24 X 1 Screw

20001X226

1

 12

Injector Cap

20001X223

1

12A Filter Conversion Kit

Incl. (1) each #9, #10, #12,
#13, #14 & (2) #11

20001X221

1

 13

Injector Seal

20001X224

1

 14

Injector Plug & O Ring Assembly

20001X217

1

 15

O Ring

20561X215

1

 16

O Ring

2000X204

1

17

Mounting Clip

20561X201

2

18

8-18 X 5/8” Screw

20561X217

2

19

Adapter Coupling

N/S

2

19A Adapter Coupling & O Ring 

Assembly Incl. (1) # 17, #18, #19 
& (2) #20

20561X215

1

20

O Ring

20561X216

4

14

Содержание UTP15-S2

Страница 1: ...SIGNATURE 2 SERIES Signature 2 Series Hydroxr Installation Operation Manual...

Страница 2: ...ontrol Start Up Procedures Page 9 Utilizing Bluetooth Page 11 Master Programming Page 12 Powerhead Assembly Page 13 Valve Body Assembly Page 14 Manifold Breakdown Page 15 Bypass Assembly Page 16 Addit...

Страница 3: ...ed from the filter by reversing the flow through the filter and running to drain Called Backwashing and lasting 10 minutes the process expands the mineral bed freeing the iron sulfur and turbidity whi...

Страница 4: ...OXR Tank to accommodate the Peroxide Feed System Filter Tank A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the water heater to prevent damage due...

Страница 5: ...around the filter 1 Position HDYROXR Tank and Filter Tank at desired location The HYDROXR tank must be installed between the well pump and pressure tank The filter tank must be installed after the pre...

Страница 6: ...to evacuate air and repressurize plumbing lines 9 Check for leaks Drain Line Connections 1 Pull out clip and remove drain line assembly located on back left side of control valve Remove drain line ho...

Страница 7: ...lug into an outlet controlled by a wall switch or pull chain that could inadvertently be turned off 2 Plug peroxide feed pump into pressure switch receptacle Pressurizing The System 1 Make certain Sig...

Страница 8: ...96 100 Straight H2O2 84 This chart is an estimation only Actual solution strength and frequency stroke setting may differ Adjust feed pump frequency stroke setting and or solution strength to achieve...

Страница 9: ...ver occur 3 Default setting is 6 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automatically 9 Control Sta...

Страница 10: ...turn and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position an...

Страница 11: ...If the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time...

Страница 12: ...ge the digits with the Set Change button and accept with the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Time...

Страница 13: ...Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Lower Back Base for Cover 20111X003 1 11 Valve Cover 20111X000 1 12 Piston Screw 20001X003 1 13 Screw SC10 3 14 Screw...

Страница 14: ...M PVC 20251X262 1 Flow Control Assy 6 0 GPM PVC 20251X263 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Flow Fitting 90 Elbow 1 2 NPT X 1 2 20251X255 1 8 Drain Retainer 20001X214 1 9 O Ring Brin...

Страница 15: ...HOSE BARB 1 4 x 1 4 NPT 1 4 65555X250 AIR INLET CHECK VALVE ASSY 1 5 65555X213 1 8 PLASTIC PIPE PLUG 1 6 65555X219 DIAPHRAGM 2 7 65555X208 MANIFOLD 1 8 65555X009 MANIFOLD O RING 1 9 65555X212 DIFFUSER...

Страница 16: ...SIGNATURE 2 SERIES Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 16 1 2...

Страница 17: ...supply 7 Reinstall cover 17 C To Replace Piston Assembly 1 Follow steps A1 A3 2 Follow steps B1 B3 3 Remove piston retaining plate screws 4 Pull upward on end of piston yoke until assembly is out of...

Страница 18: ...place pipline Pretreat to prevent Fouled media Clean media Pretreat to prevent Improper backwash setting Backwash more frequently 5 Continuous Flow to Drain Foreign material in control valve Call deal...

Страница 19: ...ion resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water p...

Страница 20: ...SIGNATURE 2 SERIES CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com...

Отзывы: