CSI UTP15-S2 Скачать руководство пользователя страница 11

 

 

                                                                                                                                                     

SIGNATURE 2 SERIES 

                                                                                                                                         

To take advantage of the Bluetooth interface this feature must be set up on a compatible Bluetooth enabled smart phones 
or tablets.

Note:

   Valves with a revision number greater or equal to “C2.00” are only compatible with Bluetooth 4.0+ (a.k.a. 

 

Bluetooth LE) Smartphones and tablets.  If you have an Android or Apple device with a compatible Bluetooth  

 

radio it can be used to connect to the valve.  Valves with a revision number less than “C2.00” are only compatible  

 

with Android devices and these valves use a Bluetooth 2.0 radio.  In the rest of this section valves with a revision  

 

number greater or equal to “C2.00” will be referred to as BTLE, valves with a revision number less than “C2.00”  

 

will be referred to as BT.

 

(The firmware revision of the valve can be viewed on the valve display for 2 seconds after the valve is powered up.)

Unfortunately due to changing Bluetooth and Tablet / Phone manufacturing standards, not all tablets and smart phones 
are compatible with all valve versions.  In general, the below table should guide you in compatibility.

BT Legacy View Valve

BTLE Legacy View Valve

Android Device with BT 4.0+

Yes

Yes

Android Device with older BT

Yes

No

Apple Device with BT 4.0+

No

Yes

1. Download and install the Legacy View app from the Google Play Store, Apple App Store or 
    www.ChandlerSystemsInc.com
2. If your valve revision is a BTLE valve you can skip this step.  Otherwise, if it is a BT valve the following steps must  

    

be followed to pair your smart phone or tablet to the control valve.  
 

• Open the settings menu on your smart phone or tablet and click on Bluetooth.

 

• Look for the softener or filter valve you want to connect to under the list of available Bluetooth devices.

 

• Select the device and pair (Default password is: 1234)

3. Open the Legacy View app
 

• Choose a valve device at any time from the list of available devices to connect to by clicking on it.

 

• If the valve you want to connect to doesn’t show up, or there is a problem connecting to a device you can  

 

  press the “Scan for Devices” button or the Legacy View logo at any time to refresh the list and start the    

 

  process over.

 

• If the valve device is a BTLE valve and it has a password other than the default password, the first time you 

 

  connect to it the app will ask you to enter the password.  After entering it the first time you should not need to  

 

  enter it again unless it changes.

4. BTLE Valve devices can be updated by the App.  When the app is updated from the Google Play Store or the    

    

Apple App Store, it may contain an updated firmware program for the valve devices.  These updates could contain  

    

new features or operational improvements. It is up to the user to allow these updates to be sent to the valve device.   

    

Uploading a new program takes approximately 1 minute.

 

 

 

FCC ID:    

 

 

SWPLV-019 or SWPEV-019-BLE

 

 

 

Name of Grantee: 

 

CHANDLER SYSTEMS, INC.

 

 

 

Equipment Class: 

 

Part 15 Low Power Communication Device

   Notes: 

   Legacy 

View 

Valve

This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, 
and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not 
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been 
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, 
if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee 
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

 - Reorient or relocate the receiving antenna.  
 - Increase the separation between the equipment and receiver.  
 - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
 - Consult the dealer or an experienced radio/TV technician for help. 

11

Utilizing Bluetooth Control 

Содержание UTP15-S2

Страница 1: ...SIGNATURE 2 SERIES Signature 2 Series Hydroxr Installation Operation Manual...

Страница 2: ...ontrol Start Up Procedures Page 9 Utilizing Bluetooth Page 11 Master Programming Page 12 Powerhead Assembly Page 13 Valve Body Assembly Page 14 Manifold Breakdown Page 15 Bypass Assembly Page 16 Addit...

Страница 3: ...ed from the filter by reversing the flow through the filter and running to drain Called Backwashing and lasting 10 minutes the process expands the mineral bed freeing the iron sulfur and turbidity whi...

Страница 4: ...OXR Tank to accommodate the Peroxide Feed System Filter Tank A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the water heater to prevent damage due...

Страница 5: ...around the filter 1 Position HDYROXR Tank and Filter Tank at desired location The HYDROXR tank must be installed between the well pump and pressure tank The filter tank must be installed after the pre...

Страница 6: ...to evacuate air and repressurize plumbing lines 9 Check for leaks Drain Line Connections 1 Pull out clip and remove drain line assembly located on back left side of control valve Remove drain line ho...

Страница 7: ...lug into an outlet controlled by a wall switch or pull chain that could inadvertently be turned off 2 Plug peroxide feed pump into pressure switch receptacle Pressurizing The System 1 Make certain Sig...

Страница 8: ...96 100 Straight H2O2 84 This chart is an estimation only Actual solution strength and frequency stroke setting may differ Adjust feed pump frequency stroke setting and or solution strength to achieve...

Страница 9: ...ver occur 3 Default setting is 6 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automatically 9 Control Sta...

Страница 10: ...turn and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position an...

Страница 11: ...If the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time...

Страница 12: ...ge the digits with the Set Change button and accept with the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Time...

Страница 13: ...Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Lower Back Base for Cover 20111X003 1 11 Valve Cover 20111X000 1 12 Piston Screw 20001X003 1 13 Screw SC10 3 14 Screw...

Страница 14: ...M PVC 20251X262 1 Flow Control Assy 6 0 GPM PVC 20251X263 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Flow Fitting 90 Elbow 1 2 NPT X 1 2 20251X255 1 8 Drain Retainer 20001X214 1 9 O Ring Brin...

Страница 15: ...HOSE BARB 1 4 x 1 4 NPT 1 4 65555X250 AIR INLET CHECK VALVE ASSY 1 5 65555X213 1 8 PLASTIC PIPE PLUG 1 6 65555X219 DIAPHRAGM 2 7 65555X208 MANIFOLD 1 8 65555X009 MANIFOLD O RING 1 9 65555X212 DIFFUSER...

Страница 16: ...SIGNATURE 2 SERIES Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 16 1 2...

Страница 17: ...supply 7 Reinstall cover 17 C To Replace Piston Assembly 1 Follow steps A1 A3 2 Follow steps B1 B3 3 Remove piston retaining plate screws 4 Pull upward on end of piston yoke until assembly is out of...

Страница 18: ...place pipline Pretreat to prevent Fouled media Clean media Pretreat to prevent Improper backwash setting Backwash more frequently 5 Continuous Flow to Drain Foreign material in control valve Call deal...

Страница 19: ...ion resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water p...

Страница 20: ...SIGNATURE 2 SERIES CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com...