CSI signature 2 SK15 Скачать руководство пользователя страница 17

 

 

                                                                                                                                                                        

SIGNATURE  2                                                                                                                                          

Ref

Description

Part No. 

Qty

1

 Piston Assembly

 20009X231

1

2

 10-24 X 13/16 Hex Head

 20001X226

3

3

 Seal and Spacer Kit

 20561X253

1

4

 End Spacer

 N/A

1

5a

DLFC 5.0 Button 

 20251X272

1

DLFC 7.0 Button

20251X273

1

6a

Flow Control Assembly 5.0

20251X262

1

Flow Control Assembly 7.0

20251X264

1

Drain Line Flow Control Housing

20251X100

1

7

Drain Line Hose Barb

20251X255

1

8

Drain Retainer Clip

 20001X214

1

9

Brine Valve 

 20009X225

1

10

Brine Line Flow Control Assy. Stainless Steel

20009X228

1

11

Brine Line Ferrule

20251X305

1

12

 Plug 

 20009X005

1

13

 10-24 X 1 Hex Screw

 20001X226

2

14

 Injector Cap Plug

 20009X010

1

15

 Injector Cover Nitro

20009X001

1

16

 Injector Seal

 20001X224

1

17

 Injector Plug

  20001X217

2

18

 Injector Screen

 20001X222

1

19

 Injector

20001X219

1

20

 Tank O-Ring

20001X215

1

21

Distributor Pilot O-Ring

20561X204

1

22

8-18 X 5/8” Hex Screw

20561X217

2

23

Clip

20561X201

2

24

Adapter Coupling

20561X215

1

25

Adapter Coupling Checkvalve

20111X011

1

26

Adapter O-Ring

20561X216

4

27

3/8” 90 Elbow

GA-Q0620626BV

1

28

Air Intake Nut

20009X014

1

29

 Stem Adapter

 GA-S0660416B

1

30

 Injection Assembly 

 20009X050

1

31

Duckbill Retainer

20009X016

1

32

Duckbill

20009X023

1

16

Содержание signature 2 SK15

Страница 1: ...SIGNATURE 2 Signature 2 Installation Operation Manual...

Страница 2: ...e oils hydrocarbon lubricants or spray silicone anywhere Petroleum base lubricants will cause swelling of o rings and seals The use of other lubricants may attack plastic Noryl It is recommended that...

Страница 3: ...146 Space Required D x W x H inches 10 X 21 X 61 13 X 24 X 61 Approximate Shipping Weight 160 254 General Specifications SK15S SK25S Catalytic Carbon 1 5 cu ft 2 5 cu ft Gravel Underbedding 20 lbs 50...

Страница 4: ...th copper or vice versa obtain di electric unions to prevent dissimilar metal corrosion Note Where the drain line is elevated above the control valve or exceeds 20 feet in length to reach the drain us...

Страница 5: ...the installation and will prevent the control valve from being plugged with floating media on initial backwash H Remove funnel and clean filter media from tank threads I Remove cap from distributor t...

Страница 6: ...softeners etc that have been exposed to iron bearing water may need to be cleaned of the precipitated iron that has been collected in them or iron bleed thru may be a problem We suggest all tanks be...

Страница 7: ...letter A in the left digit Backwash will begin at the set Backwash Time A 00 setting will cancel this feature The Max Value for this item is 29 Example Every 6 days A 06 Default Setting To Adjust this...

Страница 8: ...nd finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then...

Страница 9: ...cedures Default Min Step 1 Air Release 6 Step 2 Oxyclean NP Injection 15 sec Step 3 Short Rinse 1 Step 4 Rest 20 Steps 1 4 are non adjustable Step 5 Backwash 10 Step 6 Rest 5 Step 7 Air Replenish Opti...

Страница 10: ...5 seconds Non adjustable Step 3 Short Rinse Step For 1 minute Non adjustable Step 4 Rest Step For 20 minutes Non adjustable Step 5 Backwash Step Default of 10 minutes Step 6 Rest Step Default of 5 min...

Страница 11: ...s between positions the display will flash the number of the step it is moving towards The default time at which regeneration will occur is 12 00 a m New feature The motor s run direction during a par...

Страница 12: ...u item 2 Backwash Cycle Step Times Steps 5 6 7 8 Example 3 20 The next 4 displays set the duration of time in minutes for each backwash cycle step The step number which is currently modifiable is indi...

Страница 13: ...the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you...

Страница 14: ...SIGNATURE 2 Control Valve Powerhead Assembly 13 3 4 5 7 8 10 9 11 13 14 15 16 16 18 18 19 17 20 23 22 21 6 LETTERS IN DIAGRAM REPRESENT WIRING CONNECTIONS E M S C 1 E P P M C S 12 12...

Страница 15: ...8 Lower Front Base For Cover 20111X002 1 9 Microswitch 20251X113 1 10 Switch Spacer 20111X004 1 11 Brine Motor Mount 20111X006 1 12 Motor Assembly 20016X006 2 13 Brine Cam 20111X005 1 14 Lower Back Ba...

Страница 16: ...SIGNATURE 2 Sidekick Valve Body Assembly 15 2 1 3 9 4 8 5 10 11 12 13 15 16 18 17 20 21 14 27 29 26 23 25 24 6A 6 7 22 24A 19 14 19 31 32 28 30 AIR INJECTION ASSEMBLY Located near base of tank...

Страница 17: ...X228 1 11 Brine Line Ferrule 20251X305 1 12 Plug 20009X005 1 13 10 24 X 1 Hex Screw 20001X226 2 14 Injector Cap Plug 20009X010 1 15 Injector Cover Nitro 20009X001 1 16 Injector Seal 20001X224 1 17 Inj...

Страница 18: ...SIGNATURE 2 Tank Assembly 17 1 2 6 8 10B 9 7 4A B 3 5 20A 21 10A 20B To Injector Cap 15B 10 18 13 17 15A 10 15B 13 12 13 11 16 14 19 21 7 24 23 23 22 22 25 26 27 17 28 29 30...

Страница 19: ...le SCH80 10 20015X016 1 15b 3 Nipple SCH80 10 13 20015X015 1 16 Ball Valve 3 8 Push x 3 8 FNPT 20015X023 1 17 3 8 NPT SCH80 90 Degree Elbow 20015X014 2 18 4 Nipple SCH80 13 20015X017 1 19 6 Nipple SCH...

Страница 20: ...head assembly will now lift off easily 3 Remove piston retaining plate screws 4 Pull upward on end of piston yoke until assembly is out of valve 5 Inspect the inside of the valve to make sure that all...

Страница 21: ...er pressure should now be applied to the conditioner and any bypass line shut off 9 Check for leaks at all seal areas Check drain seal with the control in the backwash position 10 Plug electrical cord...

Страница 22: ...ine Pretreat to prevent Fouled media Clean media Pretreat to prevent Improper backwash setting Backwash more frequently 5 Continuous Flow To Drain Foreign material in control Call dealer Clean valve a...

Страница 23: ...resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water pres...

Страница 24: ...SIGNATURE 2 CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com...

Отзывы: