CSI signature 2 SK15 Скачать руководство пользователя страница 13

 

 

                                                                                                                                                                        

SIGNATURE  2                                                                                                                                          

To take advantage of the Bluetooth interface this feature must be set up on a compatible Bluetooth enabled smart phones 
or tablets.

Note:

   Valves with a revision number greater or equal to “C2.00” are only compatible with Bluetooth 4.0+ (a.k.a. 

 

Bluetooth LE) Smartphones and tablets.  If you have an Android or Apple device with a compatible Bluetooth  

 

radio it can be used to connect to the valve.  Valves with a revision number less than “C2.00” are only compatible  

 

with Android devices and these valves use a Bluetooth 2.0 radio.  In the rest of this section valves with a revision  

 

number greater or equal to “C2.00” will be referred to as BTLE, valves with a revision number less than “C2.00”  

 

will be referred to as BT.

 

(The firmware revision of the valve can be viewed on the valve display for 2 seconds after the valve is powered up.)

Unfortunately due to changing Bluetooth and Tablet / Phone manufacturing standards, not all tablets and smart phones 
are compatible with all valve versions.  In general, the below table should guide you in compatibility.

BT Legacy View Valve

BTLE Legacy View Valve

Android Device with BT 4.0+

Yes

Yes

Android Device with older BT

Yes

No

Apple Device with BT 4.0+

No

Yes

1. Download and install the Legacy View app from the Google Play Store, Apple App Store or 
    www.ChandlerSystemsInc.com
2. If your valve revision is a BTLE valve you can skip this step.  Otherwise, if it is a BT valve the following steps must  

    

be followed to pair your smart phone or tablet to the control valve.  
 

• Open the settings menu on your smart phone or tablet and click on Bluetooth.

 

• Look for the softener or filter valve you want to connect to under the list of available Bluetooth devices.

 

• Select the device and pair (Default password is: 1234)

3. Open the Legacy View app
 

• Choose a valve device at any time from the list of available devices to connect to by clicking on it.

 

• If the valve you want to connect to doesn’t show up, or there is a problem connecting to a device you can  

 

  press the “Scan for Devices” button or the Legacy View logo at any time to refresh the list and start the    

 

  process over.

 

• If the valve device is a BTLE valve and it has a password other than the default password, the first time you 

 

  connect to it the app will ask you to enter the password.  After entering it the first time you should not need to  

 

  enter it again unless it changes.

4. BTLE Valve devices can be updated by the App.  When the app is updated from the Google Play Store or the    

    

Apple App Store, it may contain an updated firmware program for the valve devices.  These updates could contain  

    

new features or operational improvements. It is up to the user to allow these updates to be sent to the valve device.   

    

Uploading a new program takes approximately 1 minute.

 

 

 

FCC ID:    

 

 

SWPLV-019 or SWPEV-019-BLE

 

 

 

Name of Grantee: 

 

CHANDLER SYSTEMS, INC.

 

 

 

Equipment Class: 

 

Part 15 Low Power Communication Device

   Notes: 

   Legacy 

View 

Valve

This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, 
and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not 
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been 
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, 
if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee 
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

 - Reorient or relocate the receiving antenna.  
 - Increase the separation between the equipment and receiver.  
 - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
 - Consult the dealer or an experienced radio/TV technician for help. 

12

Utilizing Bluetooth Control 

Содержание signature 2 SK15

Страница 1: ...SIGNATURE 2 Signature 2 Installation Operation Manual...

Страница 2: ...e oils hydrocarbon lubricants or spray silicone anywhere Petroleum base lubricants will cause swelling of o rings and seals The use of other lubricants may attack plastic Noryl It is recommended that...

Страница 3: ...146 Space Required D x W x H inches 10 X 21 X 61 13 X 24 X 61 Approximate Shipping Weight 160 254 General Specifications SK15S SK25S Catalytic Carbon 1 5 cu ft 2 5 cu ft Gravel Underbedding 20 lbs 50...

Страница 4: ...th copper or vice versa obtain di electric unions to prevent dissimilar metal corrosion Note Where the drain line is elevated above the control valve or exceeds 20 feet in length to reach the drain us...

Страница 5: ...the installation and will prevent the control valve from being plugged with floating media on initial backwash H Remove funnel and clean filter media from tank threads I Remove cap from distributor t...

Страница 6: ...softeners etc that have been exposed to iron bearing water may need to be cleaned of the precipitated iron that has been collected in them or iron bleed thru may be a problem We suggest all tanks be...

Страница 7: ...letter A in the left digit Backwash will begin at the set Backwash Time A 00 setting will cancel this feature The Max Value for this item is 29 Example Every 6 days A 06 Default Setting To Adjust this...

Страница 8: ...nd finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then...

Страница 9: ...cedures Default Min Step 1 Air Release 6 Step 2 Oxyclean NP Injection 15 sec Step 3 Short Rinse 1 Step 4 Rest 20 Steps 1 4 are non adjustable Step 5 Backwash 10 Step 6 Rest 5 Step 7 Air Replenish Opti...

Страница 10: ...5 seconds Non adjustable Step 3 Short Rinse Step For 1 minute Non adjustable Step 4 Rest Step For 20 minutes Non adjustable Step 5 Backwash Step Default of 10 minutes Step 6 Rest Step Default of 5 min...

Страница 11: ...s between positions the display will flash the number of the step it is moving towards The default time at which regeneration will occur is 12 00 a m New feature The motor s run direction during a par...

Страница 12: ...u item 2 Backwash Cycle Step Times Steps 5 6 7 8 Example 3 20 The next 4 displays set the duration of time in minutes for each backwash cycle step The step number which is currently modifiable is indi...

Страница 13: ...the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you...

Страница 14: ...SIGNATURE 2 Control Valve Powerhead Assembly 13 3 4 5 7 8 10 9 11 13 14 15 16 16 18 18 19 17 20 23 22 21 6 LETTERS IN DIAGRAM REPRESENT WIRING CONNECTIONS E M S C 1 E P P M C S 12 12...

Страница 15: ...8 Lower Front Base For Cover 20111X002 1 9 Microswitch 20251X113 1 10 Switch Spacer 20111X004 1 11 Brine Motor Mount 20111X006 1 12 Motor Assembly 20016X006 2 13 Brine Cam 20111X005 1 14 Lower Back Ba...

Страница 16: ...SIGNATURE 2 Sidekick Valve Body Assembly 15 2 1 3 9 4 8 5 10 11 12 13 15 16 18 17 20 21 14 27 29 26 23 25 24 6A 6 7 22 24A 19 14 19 31 32 28 30 AIR INJECTION ASSEMBLY Located near base of tank...

Страница 17: ...X228 1 11 Brine Line Ferrule 20251X305 1 12 Plug 20009X005 1 13 10 24 X 1 Hex Screw 20001X226 2 14 Injector Cap Plug 20009X010 1 15 Injector Cover Nitro 20009X001 1 16 Injector Seal 20001X224 1 17 Inj...

Страница 18: ...SIGNATURE 2 Tank Assembly 17 1 2 6 8 10B 9 7 4A B 3 5 20A 21 10A 20B To Injector Cap 15B 10 18 13 17 15A 10 15B 13 12 13 11 16 14 19 21 7 24 23 23 22 22 25 26 27 17 28 29 30...

Страница 19: ...le SCH80 10 20015X016 1 15b 3 Nipple SCH80 10 13 20015X015 1 16 Ball Valve 3 8 Push x 3 8 FNPT 20015X023 1 17 3 8 NPT SCH80 90 Degree Elbow 20015X014 2 18 4 Nipple SCH80 13 20015X017 1 19 6 Nipple SCH...

Страница 20: ...head assembly will now lift off easily 3 Remove piston retaining plate screws 4 Pull upward on end of piston yoke until assembly is out of valve 5 Inspect the inside of the valve to make sure that all...

Страница 21: ...er pressure should now be applied to the conditioner and any bypass line shut off 9 Check for leaks at all seal areas Check drain seal with the control in the backwash position 10 Plug electrical cord...

Страница 22: ...ine Pretreat to prevent Fouled media Clean media Pretreat to prevent Improper backwash setting Backwash more frequently 5 Continuous Flow To Drain Foreign material in control Call dealer Clean valve a...

Страница 23: ...resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water pres...

Страница 24: ...SIGNATURE 2 CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com...