Installation
- Pressurizing The System -
1. Make certain Signature Series Control Valve is in
SERVICE
position.
2. Slowly rotate bypass valve to the
SERVICE
position. (Position of bypass lever is parallel to inlet / outlet piping.)
3. Open the nearest faucet to evacuate air from plumbing lines.
4. Check for leaks! If water is observed leaking from bottom of bypass, close and open bypass lever several times to seat
o-rings. Exercise bypass valve.
5. After air is evacuated from plumbing lines, close bypass (position of bypass lever is perpendicular to the direction of
inlet pipe) on bypass valve.
Note:
Salt settings are pre-set at the factory for the maximum shown on the capacity charts.
Warning:
Do not reduce salt settings below 9 lbs. as the water level in the brine tank will not reach the grid plate.
- Programming The Control Valve -
1. Set time of day.
2. Set a.m. or p.m.
3. Set water hardness in grains per gallon (gpg).
Note:
If the water contains iron and / or manganese, multiply the total parts per million (ppm) by “four” (4) and then add to
the grains per gallon (gpg) of hardness. Use this COMPENSATED HARDNESS level when programming the
regeneration frequency.
1. Set regeneration day override if other than (7) days is desired. (This is particularly useful when iron is being treated to
prevent fouling of the resin.)
2. Set regeneration time, if other than 2:00 a.m. is desired.
Note:
Salt settings are pre-set at the factory for the maximum shown on the capacity charts.
Warning:
Do not reduce salt settings below 9 lbs. as the water level in the brine tank will not reach the grid plate.