8
Installation
-Brine Line and Overflow Connection-
1. Position brine tank on a smooth, level surface near the softener resin tank. If necessary, the brine tank can be
placed at a higher level than the resin tank, but never at a lower level.
2. Install one end of 3/8" O.D. by 1/4" I.D. brine line tubing (included with unit) to compression fitting located on left side
of control valve.
3. Remove brine tank cover.
4. Remove cap from brine well.
5. Insert opposite end of brine line through outer hole in brine tank.
6. Connect brine line to push fitting on safety brine valve located inside brine well. Replace brine well cap.
7. Install 1/2" I.D. drain line tubing (not included) to the overflow fitting on brine tank located just below the brine line.
8. Run the opposite end of brine tank drain line to a suitable drain.
- Electrical Connection -
1. Connect the power cord and plug power supply into a 115 volt / 60 Hz receptacle.
Note:
Do not plug into an outlet controlled by a wall switch or pull chain that could inadvertently be turned off
Electronic Connections
P = Power Supply
B = Powered in Backwash Step Only (Cycle #1)
S = Powered in Entire Regen. Cycle
P B S