Installation

9

Filling The Brine Tank With Salt

To expect a high level of performance and reliability, a salt manufactured specifically for water softeners must be used. 
Salt of this grade is virtually free from dirt and other particulate that would eventually cause the nitrate filter to malfunction. 
A pellet type salt is recommended, although any high quality water softener salt (such as solar salt) will suffice. The salt 
level will decrease after each regeneration cycle. Consequently, the brine tank will need to be checked and replenished 
periodically.

1. Fill the brine tank with water softener salt as described above. This will be approximately 250 pounds of salt.

Warning:

 Do not fill above level of the brine well.

2. Replace brine tank lid.

Final Check

1. Be certain the bypass valve is in the SERVICE position.
2. Make sure the power supply is connected to an uninterrupted 115 volt outlet.
3. Check that the time of day is set.
4. Double check regeneration schedule.
5. Make final check for leaks!
6. Fill out and mail warranty card.
7. Leave all manuals with unit.

Operation, Care and Cleaning

When the inlet/outlet knobs on the bypass valve are in the SERVICE position (position of bypass knobs are parallel to the 
inlet/outlet piping), water is directed through the nitrate filter. Water may be bypassed by turning the inlet/outlet knobs to 
the bypass position (position of bypass knobs are at right angles to inlet/outlet piping). Water to the home will bypass the 
nitrate filter and be untreated.

You should manually bypass the nitrate filter if:

1. The outside lines do not bypass the nitrate filter and water is to be used for lawn sprinkling or other similar uses.
2. Servicing the nitrate filter.
3. A water leak from the nitrate filter is evident.
4. Shock treating water well and piping with chlorine or other disinfectant.

Extra Regeneration

If soft water demands are usually heavy, an extra regeneration can be initiated manually:

To Skip A Regeneration

1. For vacations, or extended periods of absence, the power supply can be disconnected from the control valve.
2. Upon return, plug in cord and reset the time of day, if 9 volt battery was not installed. If battery was installed, replace    
    battery.

Содержание MN15-S2

Страница 1: ...SIGNATURE 2 SERIES Signature 2 Series Nitrate Sulfate Manual Installation Operation Manual Fully Automatic Demand Water Softeners...

Страница 2: ...ion Page 4 Control Valve Set Up Page10 Utilizing Bluetooth Page 14 Control Valve Assembly Page 15 Valve Body Assembly Page 16 Valve Body Parts Page 17 Bypass Assembly Page 18 Additional Information Pa...

Страница 3: ...alers may contain a carrier that attacks some plastic materials It is recommended that Teflon tape be used to seal plastic Noryl threaded fittings Specifications 3 General Specifications TN15 S2 MN15...

Страница 4: ...to the Nitrate System abilities to remove bi carbonate alkalinity from the water a dramatic reduction in pH of the treated water may be experienced If this occurs a whole house or upflow filter with n...

Страница 5: ...o reach the drain use 3 4 I D drain line tubing instead of 1 2 I D Drain line tubing is not included Caution If sweat soldering copper pipe remember to always use lead free solder and flux cover yoke...

Страница 6: ...with unit to compression fitting located on left side of control valve 3 Remove brine tank cover 4 Remove cap from brine well 5 Insert opposite end of brine line through outer hole in brine tank 6 Co...

Страница 7: ...ppm NO3 62 x 50 1 40 4 ppm as CaCO3 Sulfate Divide ppm mg l of Sulfate by 48 SO4 and multiply by 50 1 Example 75 ppm SO4 48 x 50 1 78 28 ppm as CaCo3 Step 2 Calculate the Nitrate Sulfate ration as CaC...

Страница 8: ...es Warning Close valve on bypass prior to selecting the backwash position After backwash position has been established slightly open bypass to evacuate air from the media tank Fully open valve when al...

Страница 9: ...ck for leaks 6 Fill out and mail warranty card 7 Leave all manuals with unit Operation Care and Cleaning When the inlet outlet knobs on the bypass valve are in the SERVICE position position of bypass...

Страница 10: ...PENSATED HARDNESS level when programming the regenera tion frequency 1 Set regeneration day override if other than 7 days is desired This is particularly useful when iron is being treated to prevent f...

Страница 11: ...xample A To accept the digit value press the Menu Enter button Once A M or P M is accepted the next menu item will flash 4 a To set the Number of Days between Regeneration A press the Set Change butto...

Страница 12: ...Signature 2 will return and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regen...

Страница 13: ...cheduled time A setting of zero will cancel this feature Example Override every 7 days A 07 default setting or cancel setting A 00 Maximum is 29 3 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3...

Страница 14: ...If the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time...

Страница 15: ...sy 21003X100 1 1 Softener Circuit Boad Assy 21001X102 1 2 Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 20001X120 1 6 Power Supply 20001X125 1 7 Back Plate 2000...

Страница 16: ...SIGNATURE 2 SERIES Valve Body Assy Softener Version 2 9 22 1 3 4 8 10 11 12 14 15 13 16 17 18 19 20 24 21 23 6 5 7 6A 16 17...

Страница 17: ...1 Flow Control Assy 5 0 GPM PVC 20251X262 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Line Fitting 90 Elbow 1 2 NPT X 1 2 Tubing 20251X255 1 8 Drain Retainer 20001X214 1 9 Brine Assembly 20561...

Страница 18: ...Assembly Ref Description Part Qty 1A Meter Assembly Turbine Complete 20003X200 1 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless St...

Страница 19: ...assembly will now lift off easily 4 Put new powerhead on top of the valve Be sure the drive pin on main gear engages slot in drive yoke wide side of drive yoke upright must face to the left away from...

Страница 20: ...trol valve cover Disconnect the meter signal wire from the meter 3 Remove screw and washer at piston drive yoke Remove powerhead mounting screws The entire powerhead assembly will now lift off easily...

Страница 21: ...ter is over it Resin fouling Call dealer Find out how to confirm it Clean the resin and prevent future fouling Poor distribution channeling uneven bed surface Call dealer Check backwash flow Regenerat...

Страница 22: ...connectionsfor air leaks Internal control leak Call dealer Check piston seals and spacers for scratches and dents 9 Continuous Flow to Drain Foreign material in control piston and seals Call dealer C...

Страница 23: ...tion resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water...

Страница 24: ...SIGNATURE 2 SERIES CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com...

Отзывы: