SYMPTOMS
PROBABLE CAUSE
CORRECTION
5. High salt usage
High salt setting
Adjust brine tank refill time
Excessive water in brine tank
See symptom # 7.
Constant flow through the unit
Indicates plumbing leak (i.e. toilet
tank)
Improperly set hardness
Reset programming
6. Loss of water
pressure
Scaling / fouling of inlet pipe
Clean or replace pipeline.
Pretreat to prevent.
Fouled resin
Clean resin. Pretreat to prevent.
Improper backwash
Too many resin fines and/or sediment.
Call dealer. Reset backwash flow rate,
and/or adjust.
7. Excessive water in
brine tank and/or
salty water to
service
Plugged drain line
Check flow to drain. Clean flow
control.
Dirty or damaged brine valve
Clean or replace brine valve.
Plugged injector
Clean injector and replace screen.
Low inlet pressure
Increase pressure to allow injector to
perform properly. (20 psig minimum)
Excessive brine refill cycle time
Reset brine refill cycle time.
8. Softener fails to
use salt
Check items listed in #1
Improper control valve programming
Check and reset programming
Plugged/restricted drain line
Clean drain line and/or flow control
Injector is plugged
Clean or replace injector and screen
No water in brine tank
Check for restriction in BLFC. Ensure
safety float is not stuck. Check brine
tank for leaks.
Water pressure is too low
Line pressure must be at least 20 psi.
Brine line injects air during brine draw
Check brine line for air leaks
Internal control leak
Call dealer. Check piston, seals and
spacers for scratches and dents.
9. Control cycles
continuously
Faulty circuit board
Replace circuit board.
10. Continuous flow to
drain
Foreign material in control
Call dealer. Clean valve, rebuild unit.
Internal control leak
Same as above.
Valve jammed in backwash, brine or rapid
rinse position
Same as above.
Motor stopped or jammed.
Replace motor.
Содержание LV-019
Страница 12: ...Signature 2 Series pg 12 Control Valve Assembly Nitro Nitro Pro ...
Страница 13: ...Signature 2 Series pg 13 NITRO NITRO PRO BODY ASSEMBLY ...
Страница 15: ...Signature 2 Series pg 15 Control Valve Drive Assembly Filter Version ...
Страница 17: ...Signature 2 Series pg 17 Control Valve Assembly Softener Version ...