pg. 24
Troubleshooting Guide
SYMPTOM
PROBABLE CAUSE
CORRECTION
1. Softener fails to
regenerate
automatically
Power supply plugged into intermittent or
dead power source
Connect to constant power source
Disconnected meter cable
Reconnect cable
Improper control valve programming
Reset program settings
Defective power supply
Replace power supply
Defective circuit board or meter
Replace or repair
Defective drive motor
Check motor operation by activating
the service button on back of motor
2. Regeneration at
wrong time
Time of day improperly set, due to power
failure
Reset time of day programming and
install 9-volt battery
Regeneration time set improperly
Reset regeneration time programming
3. Loss of capacity
Increase raw water hardness
Reset unit to the new capacity
Brine concentration and/or quantity
Keep brine tank full of salt at all times.
Clean it yearly. Salt may be bridged.
If using a salt grid plate, ensure refill
water is over it.
Resin fouling
Call dealer. Find out how to confirm it.
Clean the resin and prevent future
fouling.
Poor distribution, channeling (uneven bed
surface)
Call dealer. Check distributors and
backwash flow.
Internal valve leak
Call dealer. Replace spacers, seals
and/or piston.
Resin age
Call dealer. Check for resin oxidation
caused by chlorine. Mushy resin.
Resin loss
Call dealer. Check for correct bed
depth. Broken distributors. Air or gas
in bed: well gas eliminator. Loose
brine line.
4. Poor water quality
Check items listed in #1, #2, & #3
Bypass valve open
Close bypass valve.
Channeling
Check for too slow or high service
flow. Check for media fouling.
Содержание LV-019
Страница 12: ...Signature 2 Series pg 12 Control Valve Assembly Nitro Nitro Pro ...
Страница 13: ...Signature 2 Series pg 13 NITRO NITRO PRO BODY ASSEMBLY ...
Страница 15: ...Signature 2 Series pg 15 Control Valve Drive Assembly Filter Version ...
Страница 17: ...Signature 2 Series pg 17 Control Valve Assembly Softener Version ...