Fiberlink®

3X3X Series

Models 3134/3135 & 3334/3335

10 Channel Video Multiplexer/Demultiplexer

World Headquarters

55 Cabot Court

Hauppauge, New York 11788  USA

Tel:   (631) 273-0404

Fax:  (631) 273-1638
[email protected]

Asia

Communications Specialties Pte Ltd

100 Beach Road

#22-09 Shaw Tower

Singapore 189702

Tel:  +65 6391 8790

Fax:  +65 6396 0138
[email protected]

commspecial.com

Communications Specialties’ Fiberlink® 3X3X

User’s Manual

The all-digital Fiberlink® 3X3X 

series allows you to multiplex 

up to 10 video channels along 

with optional RS-Type data onto 

a single fiber optic core offering 

unsurpassed signal distribution 

efficiency. Fiberlink 3134 is 

compatible with Fiberlink Matrix 

offering you the ability to route 

up to 320 video signals. 

Содержание Fiberlink 3 Series

Страница 1: ...Shaw Tower Singapore 189702 Tel 65 6391 8790 Fax 65 6396 0138 csiasia commspecial com commspecial com Communications Specialties Fiberlink 3X3X User s Manual The all digital Fiberlink 3X3X series all...

Страница 2: ...ideo Specifications 4 Data Specifications 5 Optical Loss Budgets 5 Maximum Useable Distance 5 Installation Instructions 6 Alarm Switch Settings 7 Alarm Output Settings 7 Data Configuration Procedure 8...

Страница 3: ...ignals Fiberlink 3334 adds RS Type Data to the same fiber optic cable Features No adjustments pure digital processing and transmission Full color uncompressed real time transmission in NTSC PAL or SEC...

Страница 4: ...e 0 to 55 degrees C Relative Humidity 10 90 non condensing Operating Power 95 250 VAC 47 63 Hz Size 1 75 H x 16 75 W x 10 D inches 44 H x 425 W x 254 D mm Weight Approx 5 5 lbs 2 5 kg Fiberlink Matrix...

Страница 5: ...s Budgets and Maximum Useable Distance Data Specifications Loss Budgets Maximum Distance 1310 nm S Version Fiber Type Loss Budget Distance Single Mode Fiber 0 20 dB 55km Multimode Fiber 62 5u 0 20 dB...

Страница 6: ...iver units 5 When power is applied the green POWER LED should illuminate indicating the presence of operating power The Video LEDs will give an indication as described in the Indicator LED s and Alarm...

Страница 7: ...larm Switch Settings Options When an alarm condition occurs the red Alarm LED on the front panel will blink the inter nal piezo sounder will beep and the external contacts will be activated see Alarm...

Страница 8: ...the rear panel connectors labels DATA ALARM on both the transmitter and receiver units 5 If there is no fiber optic cable connecting the transmitter and receiver at this time connect an optical cable...

Страница 9: ...5 6 7 8 9 10 11 12 2400 4 73ms 1 2 3 4 5 6 7 8 9 10 11 12 19 2k 620 sec 1 2 3 4 5 6 7 8 9 10 11 12 76 8k 150 sec 1 2 3 4 5 6 7 8 9 10 11 12 9600 1 10ms 1 2 3 4 5 6 7 8 9 10 11 12 57 6k 180 sec 1 2 3...

Страница 10: ...7 8 9 10 DATA ALARM 1 2 3 4 5 6 7 8 9 10 DATA ALARM Terminal Block Receptacle on Unit Terminal Block Receptacle on Unit PIN 1 Signal Common PIN 2 Signal to be transmitted over fiber PIN 4 Signal being...

Страница 11: ...k Receptacle on Unit Terminal Block Receptacle on Unit PIN 1 Shield Ground PIN 2 Signal to be transmitted received over from fiber PIN 3 Signal to be transmitted received over from fiber PIN 1 Shield...

Страница 12: ...lure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal connections are correct An optical power meter such as the...

Страница 13: ...light transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink...

Страница 14: ...cluding free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipme...

Страница 15: ...Power Meter measures the power of optical signals at 850 980 1310 and 1550 nm wavelengths allowing for convenient on site testing of fiber networks during construction and maintenance procedures It ca...

Страница 16: ...Road 22 09 Shaw Tower Singapore 189702 Tel 65 6391 8790 Fax 65 6396 0138 csiasia commspecial com commspecial com 2010 Communications Specialties Inc All Rights Reserved Fiberlink and the starburst lo...