CSI CSI-DSP85-PS7 Скачать руководство пользователя страница 17

-17-

OIP3

Measured with 2 CW tones at 14

dBm/tone

Linear Output Power

+ 27dBm max

Uplink and Downlink

                                                          SMR +26dBm**                   ** AGC Set Point

Noise Figure (Avg)

     5.0 dB

At Maximum Gain

Maximum RF input Power                  

+10 dBm

without damage

Linear Gain

 85 dB

Factory Calibrated Gain

Pass Band Ripple

  +/-1.5 dB

Automatic Gain Control (AGC)

 30 dB max

In 0.5 dB steps

     range

Manual Gain Control

 53.5-85 dB max

In 0.5 dB steps

RMS Vector Error (EVM)

  3% max           TDMA, EDGE, W-CDMA, CDMA2000, P25

CDMA RHO

  0.98 min

CDMA2000, 1x-EVD0

Spurious Emissions &
Applicable Documents

FCC

-13 dBm max

Per FCC part 2 and 90

Industry Canada

-13 dBm max

Propagation Delay

      <2.5 usec

Input VSWR (Typ)                                 

<1.5:1

+ 43 dBm

Environmental Requirements

Relative Humidity

5% to 95%

Non-condensing

Industrial Dust

   <15mg/m3

Telcordia GR-63-CORE

Temperature Range                          

   0  to +50  C

                                                           (-32  to +122  F)

0

0

0

   0

1dB Compression

Uplink and Downlink

+ 33 dBm

Connectors

 N-Female (2)

Operating Power Parameters

Parameter

Specification

Notes

Parameter

Specification

Notes

Содержание CSI-DSP85-PS7

Страница 1: ...CSI DSP85 PS7 CSI DSP85N PS7 CSI DSP85 PSS8 CSI DSP85N PSS8 Installation Manual...

Страница 2: ......

Страница 3: ...Model 13 Dry Contact Terminal 14 Optional Accessories 14 Circuit Operational Description 15 Important Installation Notes 15 Functional Block Diagram 15 Mechanical Specifications Weather Resistent Mode...

Страница 4: ...r otherwise alter the grounding lug on the power cord Explosive Atmospheres To avoid explosion or fire do not operate this product in the presence of flammable gases or fumes Lightning Danger Do not i...

Страница 5: ...filter set configurations stored in memory determine the unit s adaptability to various field applications The following pages describe the public safety band plan as well as the convention CSI uses...

Страница 6: ...MHz 2nd Channel Block Downlink Stop Freq of 773 0000 MHz with standard guard band Band ID Start Channel 1st Block see formula End Channel 1st Block see formula Underscore Indicates the Gap Between Ch...

Страница 7: ...k Start Freq of 866 1000 MHz 2nd Channel Block Downlink Stop Freq of 867 0125 MHz with standard guard band Band ID Modulation ID Start Channel 1st Block see formula End Channel 1st Block see formula U...

Страница 8: ...condition such as insufficient antenna isolation and will need to be addressed by either the system software or a technician to be reset to original system settings using the GUI or menu driven user i...

Страница 9: ...ph Display ILLUMINATED BARS SIGNAL AT INPUT CONNECTOR 0 1 2 3 10 81 dBm 81dBm to 79dBm 78dBm to 75dBm Adjacent Channel Interference 4 5 6 7 8 9 74dBm to 71dBm 70dBm to 67dBm 66dBm to 63dBm 62dBm to 59...

Страница 10: ...o reject these unwanted signals In some instances the donor antenna can be reoriented horizontally to place the interference source in an antenna pattern null There also may be some cases where the in...

Страница 11: ...Attenuator Selection Guidelines Accurate attenuator values need to be chosen to ensure that the maximum total power higher of Composite or In Band Input applied to the donor and server port s does no...

Страница 12: ...PLATE OPTIONAL 5 1EA 750 2172 002 P S MOUNTING BRACKET X WILL VARY WITH MODEL AND BAND ORDERED The following diagram illustrates the best method for mounting the repeater to a wall in an typical inst...

Страница 13: ...ation Note for optimal cooling the unit should be mounted vertically on a wall with the antenna ports down ITEM QTY PART DESCRIPTION 1 1EA CS10 XXX 4XX DSP85N REPEATER 2 1EA 750 2268 001 MOUNTING PLAT...

Страница 14: ...698 2 2K 7 10 UPS Battery backup 2 hr Single band 1 hour dual band model number CS48 985 600 Battery backup 4 hr Single band 2 hour dual band model number CS48 985 601 Power Dividers 2 1 model number...

Страница 15: ...then processes the resultant digitized IF signal that was previously generated by an Analog to Digital Converter The processed filtered digital signal is fed to a Digital to Analog converter and then...

Страница 16: ...Height 4 69 in Width 18 62 in Depth 11 25 in Heat Output 500 BTU Hr Color Satin Black Box Weight 35 5 16 103 lbs kg Box Thermal Management Convection cooled Large heatsink Surface Coating Powder Coat...

Страница 17: ...dB steps RMS Vector Error EVM 3 max TDMA EDGE W CDMA CDMA2000 P25 CDMA RHO 0 98 min CDMA2000 1x EVD0 Spurious Emissions Applicable Documents FCC 13 dBm max Per FCC part 2 and 90 Industry Canada 13 dB...

Страница 18: ...18 CC NC NO ETHERNET USB COM 1 COM 2 POWER DL PWR ALARM UL PWR TO OUTSIDE ANTENNA TOINSIDE ANTENNA Mechanical Drawing Standard Model...

Страница 19: ...19 Mechanical Drawing Weather Resistent Model TOINSIDE ANTENNA TOOUTSIDE ANTENNA USB ETHERNET POWER CC NC NO...

Страница 20: ...hat has a static IP Select Use the following IP Address and enter the IP Address as follows 192 168 1 x where x any number from 2 to 254 inclusive other than 100 The subnet mask is 255 255 255 0 Quest...

Страница 21: ...software version 2 2 4 or prior only letters numbers and underscores are acceptable nomenclature In units with software version 2 3 0 and up Underscores are not acceptable however hyphens are accepta...

Страница 22: ...the Program a Filter page below The user may select the desired filter by pressing the band sub band and modulation selection buttons Undesired bands sub bands if lit will require the user to manually...

Страница 23: ...ofessional for proper setting requirements If the repeater includes a modem kit click on Remote Network in the navigation box and the screen below is displayed Highlight the carrier on whose network t...

Страница 24: ...Contact CSI for updates and instructions System Health Install Upload The user may clear LED indicators alarms and the Event Log by clicking the Clear Log button If required in your municipality visi...

Страница 25: ...are the only acceptable nomenclature for the Location field and hyphens may not be used as the first or last character Email Configuration page allows the user to enter up to five Email addresses to w...

Страница 26: ...ss to the repeater TMI also known as the console interface is made by connecting a serial cable optional as shown in figure 1 from the serial connector of the laptop to either of the serial ports on t...

Страница 27: ...e latest TeraTerm Pro Web release Version 3 1 3 October 8 2002 ttpro313 zip When the program is started the following screen is displayed Select the Serial radio button and press OK as shown below Not...

Страница 28: ...og screen Go to the setup dropdown menu and select Serial port to make changes to the serial port setup Configure the terminal program for the correct COM port in this case COM 1 and 115200 baud rate...

Страница 29: ...r entering the password and pressing return the TMI main menu will appear Note by default the Set Parameters option is disabled To re enable the user will press 1 and will be prompted for a username a...

Страница 30: ...by typing the desired gain at the prompt The user is then returned to the previous menu Each Set Parameter selection when chosen will be expanded to allow changing or setting of that parameter For exa...

Страница 31: ...he IP addresses of both the computer used and the repeater must use the same group of IP address number sets For example the repeater ships with the default IP address of 192 168 1 100 and a Sub Net M...

Страница 32: ...h will require the user to log in The default user name is user The default password is csi1234 In the field after the prompt type the user name and password After typing the password press the enter...

Страница 33: ...become fully functional contact the service provider In addition an IP address must be obtained and entered into the CSI DSP85 PSS8 Once the modem has been installed and activated it can be accessed...

Страница 34: ...on your Windows computer Click in the Network Connections Icon in the Control Panel See below Right click on Local Area Connection and select Properties Scroll down to Internet Protocol TCP IP and cli...

Страница 35: ...ered Click OK then OK again and retry connection A crossover Ethernet cable supplied must be used for Web Interface access As a reminder you must verify the Ethernet port on your laptop is powered If...

Страница 36: ...about one tenth of RBW Other settings like span are whatever is appropriate One should also make sure that there are no signals above the top of the screen If you cannot see an adjacent out of band si...

Страница 37: ...r ranty shall be applicable with respect to any product which Seller replaces pursuant to it SELLER MAKES NO WAR RANTY EXPRESS OR IMPLIED OTHER THAN AS SPECIFI CALLY STATED ABOVE EXPRESSLY EXCLUDED AR...

Страница 38: ...Indicators 7 Lightning Danger 4 Linear Gain 16 Liner Output Power 16 Local Network 20 login 19 M Manual Gain Control 16 Maximum RF input Power 16 Modem Interface 32 modulation selection 21 Monitoring...

Страница 39: ...39 Notes...

Страница 40: ...960 1041 005 rev B ECO 2241...

Отзывы: