![CSI CSI-DSP85-PS7 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/csi/csi-dsp85-ps7/csi-dsp85-ps7_product-manual_2692660014.webp)
-14-
Warning
: On the standard model, power supply cable connectors are keyed for proper orientation, but if forced can be
inserted incorrectly. Great care should be taken to avoid this as it may damage the connectors and/or the repeater. This does
not apply to the weather resistent model, which uses an internal power supply
Keyed for proper alignment, do not force
connector into place.
A complete line of accessories is available from Cellular Specialties, Inc. Check with your CSI distributor for any additional items
needed. Below are just a few examples suitable for most in-building needs.
•
Directional Couplers
6dB - model number:
CSI-DC6/700-2K/N
10dB - model number:
CSI-DC10/700-2K/N
15dB - model number:
CSI-DC15/700-2K/N
20dB - model number:
CSI-DC20/700-2K/N
30dB - model number:
CSI-DC30/700-2K/N
•
Outside Donor Antenna
Yagi - model number:
CSI-AY/806-960/14
Panel - model number:
CSI-AP/698/2.2K/7-10
•
UPS
Battery backup, 2 hr Single band
1 hour dual band - model number:
CS48-985-600
Battery backup, 4 hr Single band
2 hour dual band - model number:
CS48-985-601
•
Power Dividers
2:1 - model number:
CSI-SPD2/700-2.5K/N
3:1 - model number:
CSI-SPD3/700-2.5K/N
4:1 - model number:
CSI-SPD4/700-2.5K/N
•
Grounding Kit
- model number:
CSI-GKIT
•
Lightning Arrestor
- model number:
CSI-CAP
•
Inside Omnidirectional Antenna
Quad-band - model number:
CSI-AO/700/2.5K/3
•
Mounting Kit
19” rack or wall mountable -
model number:
CSI-RWM-DSP85
Optional Accessories
This CSI Digital Repeater is equipped with an automatic amplifier safety shutdown circuit that will disable the transmitter, to prevent excessive
intermodulation and oscillation, should the uplink or downlink overloads be reached. The amplifier will periodically attempt to recover from this condition.
In order to provide an indication of this shutdown, a terminal block mounted externally is provided for remote monitoring. Terminals 1 and 2, labeled NO
and NC respectfully, will toggle from open to close with major faults.
Dry Contact Terminal
Содержание CSI-DSP85-PS7
Страница 1: ...CSI DSP85 PS7 CSI DSP85N PS7 CSI DSP85 PSS8 CSI DSP85N PSS8 Installation Manual...
Страница 2: ......
Страница 19: ...19 Mechanical Drawing Weather Resistent Model TOINSIDE ANTENNA TOOUTSIDE ANTENNA USB ETHERNET POWER CC NC NO...
Страница 39: ...39 Notes...
Страница 40: ...960 1041 005 rev B ECO 2241...