ALFA LAVAL UNIQUE MIXPROOF TANK OUTLET VALVE INSTRUCTION MANUAL—REV 8/21
4 Operation
The valve is designed for cleaning in place (= CIP).
Study the instructions carefully and pay special attention to the warnings!
NaOH = Caustic Soda. HNO
3
= Nitric acid.
Internal leakage in the valve is externally visible by means of the leakage outlet.
S
Stteepp 55
1. Avoid excessive concentration of the cleaning agent
⇒
D
Doossee ggrraadduuaallllyy!!
2. Adjust the cleaning flow to the process
M
Miillkk sstteerriilliizzaattiioonn//vviissccoouuss lliiqquuiiddss
⇒
IInnccrreeaassee tthhee cclleeaanniinngg fflloow
w!!
S
Stteepp 66
V
Vaallvvee ppnneeuum
maattiicc ooppeerraattiioonn dduurriinngg iinn--ppllaaccee cclleeaanniinngg
Each valve seat shall be lifted during the length of the cleaning cycle.
Seat lift durations shall not exceed 10 seconds.
These pneumatic functions include:
1. Upper valve seat lift (takes place during cleaning of upper valve body)
2. Lower valve seat push (takes place during cleaning of lower valve body)
The following chart presents an overview of these functions together with the recommended time durations at 21psi (1.5 bar) CIP
pressure. It is recommended to do seat lift/push in the middle of each step in the CIP sequence.
C
CIIP
P eevveenntt @
@ lleennggtthh
V
Vaallvvee ffuunnccttiioonn
V
Vaallvvee
ssoolleennooiidd nnoo..
S
Soolleennooiidd
m
mooddee
A
Accttuuaall ooppeenniinngg
ttiim
mee
N
Nuum
mbbeerr ooff lliiffttss//ppuusshh
iinn eeaacchh C
CIIP
P sstteepp
Upper seat lift
3
Energized
*0.5 sec
3
Lower seat lift
2
Energized
*0.5 sec
3
SpiralClean vent
-
-
*0.5 sec
3
Warm pre-rinse @
3 minutes
OD cleaning
-
-
*5 sec
2
Upper seat lift
3
Energized
*0.5 sec
3
Lower seat lift
2
Energized
*0.5 sec
3
SpiralClean vent
-
-
*0.5 sec
3
Hot alkaline wash
@ 10 minutes
OD cleaning
-
-
*5 sec
2
Upper seat lift
3
Energized
*0.5 sec
3
Lower seat lift
2
Energized
*0.5 sec
3
SpiralClean vent
-
-
*0.5 sec
3
Cold post wash @
3 minutes
OD cleaning
-
-
*5 sec
2
Upper seat lift
3
Energized
*0.5 sec
3
Lower seat lift
2
Energized
*0.5 sec
3
SpiralClean vent
-
-
*0.5 sec
3
Cold acidified rinse
@ 3 minutes
OD cleaning
-
-
*5 sec
2
*Time stated is the actual opening time for the valve. Programmed duration is depended on the access to compressed air and response
time from PLC.
Variations caused by compressed air are typically:
- Long compressed air supply hoses.
- Small ID on air supply hoses.
- Limited availability of compressed air.
S
Stteepp 77
A
Allw
waayyss rinse well with clean water after the cleaning.
N
NO
OTTE
E!!
The cleaning agents must be stored/disposed of in accordance
with current rules/directives.
P
Paayy ssppeecciiaall aatttteennttiioonn ttoo ssppiillllaaggee ooff hhoott cclleeaanniinngg fflluuiidd//w
waatteerr..
A
Allw
waayyss rriinnssee!!
Clean water Cleaning agents
17