background image

32" O.C. MAX.

[812.8mm]

P-OMAN HANDRAIL

TYPICAL HANDRAIL ASSEMBLY

24POMAN

1.

USING "LOCAL CODE" REQUIREMENTS, ESTABLISH HANDRAIL HEIGHT ABOVE FINISH FLOOR.  DEDUCT 3 3/8" [85.7mm] AND SNAP A CHALK
LINE AT THAT HEIGHT.  THIS MARKS THE LOCATION OF THE HOLE FOR THE MOUNTING BRACKET FASTENERS.

2.

DRILL CLEARANCE HOLES IN WALL SURFACE FOR MOUNTING HARDWARE.  REFERENCE CHART ON PAGE 2 FOR CORRECT DRILL
DIAMETERS.

3.

INSTALL MOUNTING BRACKETS USING APPROPRIATE FASTENERS.  DO NOT OVER TORQUE FASTENERS.  USE A LEVEL TO ENSURE THAT

THE BRACKETS ARE LEVEL.

NOTE:  SEE LAYOUT VIEW TO AID IN MOUNTING BRACKET LOCATION.

4.

CUT THE CONTINUOUS POWDER COATED HANDRAIL TO LENGTH USING THE REQUIRED DEDUCTIONS (REFERENCE LAYOUT VIEW).

NOTE:  IT IS RECOMMENDED THAT CONTINUOUS POWDER COATED HANDRAIL BE CUT WITH AN 80-100 TOOTH CARBIDE TIPPED SAW BLADE OR
EQUIVALENT.

5.

ATTACH END CAPS AND OUTSIDE CORNERS:

·

ALIGN HANDRAIL WITH END CAP SO THEY ARE FLUSH TOGETHER.

·

USING OUTSIDE MOUNTING PLATE AS A TEMPLATE, PLACE INTO GROOVE AND MARK THE HOLE LOCATIONS.

·

REMOVE OUTSIDE MOUNTING PLATE AND DRILL HOLES (

 1/8" DRILL).

·

ALIGN HOLES OF INSIDE MOUNTING PLATE, HANDRAIL AND OUTSIDE MOUNTING PLATE.

·

ATTACH USING #6-32 x 3/4" FH MACHINE SCREWS.  DO NOT FULLY SECURE.

·

REPOSITION END CAP AND ATTACH USING #6-32 x 3/4" FH MACHINE SCREWS.

·

SECURELY TIGHTEN ALL FASTENERS.

6.

DRILL 1/16" PILOT HOLES INTO THE POWDER COATED HANDRAIL FOR MOUNTING BRACKET ATTACHMENT.  MOUNTING BRACKETS ARE TO
BE LOCATED 3" [76.2mm] FROM EACH END OF THE POWDER COATED HANDRAIL AND 32" [612.6mm] ON CENTER ALONG LENGTH, AS
REQUIRED.

7.

FASTEN THE POWDER COATED HANDRAIL TO THE WALL BRACKETS IN SUCCESSION BY INSERTING TWO #6 x 5/8" PHILLIPS FLAT HEAD
SHEET METAL SCREWS THROUGH THE UNDERSIDE OF BRACKET INTO THE POWDER COATED HANDRAIL.  CAUTION: OVER-TORQUEING
MAY CAUSE THE FASTENERS TO STRIP.

POWDER COATED

HANDRAIL END CAP

POWDER COATED HANDRAIL

POWDER COATED
HANDRAIL OUTSIDE
CORNER

FASTENER #5

HANDRAIL END CAP
OUTSIDE MOUNTING PLATE

FASTENER #3

HANDRAIL SPLICE
PLATE WITH
FASTENER #3

HANDRAIL END CAP
INSIDE MOUNTING PLATE

POWDER COATED

HANDRAIL END CAP

SPECIFIED FASTENER

PLATFORM MOUNTING BRACKET

Doc#: II-24POMAN

Issue Date: 03/23/10

Rev Date: 11/09/18

Содержание P-OMAN

Страница 1: ...IZE EXPANSION AND CONTRACTION 9 MAY REQUIRE USE OF FIRE PUTTY WHEN INSTALLED ON FIRE WALL WITH TOGGLE BOLTS REFERENCE INSTRUCTIONS 24FIREPUTTY FOR FIRE PUTTY INSTALLATION 10 THIS HANDRAIL REQUIRES A M...

Страница 2: ...OUTSIDE CORNER ASSEMBLY FASTENER 6 1 4 FLAT WASHER 90H007003 FASTENER 7 1 4 20 X 3 4 HEX HEAD MACHINE SCREW 90H008002 P OMAN HANDRAIL COMPONENTS WALL FASTENERS 24POMAN FASTENER 4 10 24 X 1 2 ROUND HE...

Страница 3: ...ENGTH 1 8 3 2mm P OMAN HANDRAIL LAYOUT VIEW 24POMAN POWDER COATED HANDRAIL LENGTH 3 76 1mm 1 25 5mm 3 76 2mm MAX FIRST BRACKET LOCATION FROM CORNER OF WALL 3 76 2mm 4 101 6mm ALUMINUM CRASH RAIL RETAI...

Страница 4: ...HANDRAIL OUTSIDE CORNER CRASH RAIL OUTSIDE CORNER ASSEMBLY FASTENER 3 HANDRAIL SPLICE PLATE WITH FASTENER 3 RC 10 CUSHION ACROVYN CRASH RAIL COVER ALUMINUM CRASH RAIL RETAINER FASTENER 5 HANDRAIL END...

Страница 5: ...GROOVE AND MARK THE HOLE LOCATIONS REMOVE OUTSIDE MOUNTING PLATE AND DRILL HOLES 1 8 DRILL ALIGN HOLES OF INSIDE MOUNTING PLATE HANDRAIL AND OUTSIDE MOUNTING PLATE ATTACH USING 6 32 x 3 4 FH MACHINE S...

Страница 6: ...Y ALIGNING THE HEX HEAD BOLT WITH THE MOUNTING BRACKETS AND INSERTING THE HEX HEAD BOLT INTO THE MOUNTING BRACKET HOLE PLACE A 1 4 FLAT WASHER AND 1 4 20 HEX NUT ONTO THE HEX HEAD BOLT AND TIGHTEN AS...

Страница 7: ...UTSIDE CORNER INSTALLATION 1 ATTACH ALL OUTSIDE CORNERS USE OUTSIDE CORNER AS A TEMPLATE TO DRILL 7 32 PILOT HOLES IN RETAINER ATTACH OUTSIDE CORNERS BY SLIDING THE CORNER ONTO THE END OF THE ALUMINUM...

Отзывы: