Striker face 
plate

11

11

Position the striker face plate in the 

centre of the striker body - this may need to 
be adjusted in the steps following. Insert the 
striker face plate screws and loosely tighten.

12

Close the door. When the striker is fitted 

correctly the magnet will draw the plunger 
forward. If this does not happen the striker is 
misaligned with the plunger (see below). If the 
alignment is correct, tighten the screws and 
skip to Step 14; otherwise continue to Step 13.

12

13

Striker 
face plate 
screws

2.5mm 

(3/32”)

2.5mm 

(3/32”)

Striker

Plunger

13

The striker allows 2.5mm (3/32”) of 

adjustment in each direction when the 
striker face plate is fitted in the centre of  
the striker body.
To adjust the face plate position, loosen 
the striker face plate screws slightly and 
adjust the face plate up or down to allow 

14

Manually push the plunger forward until 

there is no gap between spring reservoir one 
(SR1) and spring reservoir two (SR2).
Restrain the plunger nut using the large end 
of one of the two identical supplied spanners.

Push 
here

SR1 SR2

No gap

14

Turn 
clockwise

15

15

Place the small end of the second spanner 

across the flats under the head of the plunger.
Keep the spanner restraining the plunger nut 

stationary while turning the second spanner 

clockwise.
Continue to turn the spanner until there is no 
longer a gap between the spanner and the 
shroud face. 
Now turn the spanner anti clockwise half a turn. 
The plunger should now be adjusted correctly. 
Slide the door closed to check that it latches. 
If the snib button is hard to push down or the 
plunger doesn’t engage with the striker, adjust 
as necessary.

Front View Rear View

16

If installing a snib/snib or a snib one 

side privacy handle proceed to Step 17, 
otherwise, fit the emergency release button 
(with the spring attached) into the two holes  
in the arm of the locking slider

17

16

Emergency 
release 
button

Locking 
slider arm

Front 
flange

17

Fit the remaining side handle to the 

chassis (using the 3x side handle to chassis 
screws
) by sliding the front flange of the 
handle under the heads of the three screws. 
Tighten the screws.

Spring
(attached)

18

Fit the privacy face plate to the 

chassis using the 3x handle face plate 
screws
.

Handle face 
plate screws

Privacy 
face 
plate 

8

Remove the striker from its box. Remove 

the striker face plate from the striker body. 
Insert the 2x striker nuts into the recess in the 
back of the striker body.
Insert the 2x striker face plate screws through 
the slot in the front face of the striker body 
and into the striker nuts. Loosely tighten the 
screws.

Striker nuts

Striker 
nuts

Rear View

Striker body

7

Open the door. Transfer the horizontal line 

across the centre of the closing jamb. This 
line represents the top of the striker cut out.
A double-sided striker cut out template has 
been provided:
- Use template labelled ‘FLUSH striker 

template’ if you are installing a snib/

emergency or snib/snib privacy handle
- Use template labelled ‘RECESSED striker 

template’ if you are installing a snib one side 

privacy handle.

32 40

32 40

40 32

40 32

2

3

7

CL

5

4

6

Horizontal 
line

Centre of  
closing jamb/
centre of 
door closing 
position

CL

7

Striker 
body

Striker face 
plate screws

Striker 
mounting 
wood screws

10

Striker face 
plate screws

9

Insert the striker body, with the striker 

face plate screws and the striker nuts 
attached, into the cut out in the closing 
jamb. 

Striker 
face 
plate 
screws

9

10

Remove the striker face plate screws.  

The striker nuts are now trapped in position.

18

5

7

6

8

PAGE

PAGE

PAGE

PAGE

Fitting Emergency Release

Adjusting the Plunger

Fitting the Remaining Side Handle

Fitting the Face Plate

Gap

No 

gap

Striker face 
plate screws

8

Screw the 4x striker mounting wood screws 
into the closing jamb.

© Cavity Sliders Limited. CAVILOCK

®

 CL400

®

 MAGNETIC (O.D. 2013) PRIVACY INSTRUCTIONS.  

60905/CL400ZA925 - 05.2017 

All copyright and other property in this document is reserved by Cavity Sliders Limited. Details and specifications are subject to 

change without notice. Whilst all care is taken to ensure the accuracy of all information, no responsibility will be accepted for any 

errors or omissions. ® CS FOR DOORS, CS CAVITY SLIDERS and CAVILOCK are Registered Trademarks. Patents pending.

Fitting the Striker

Fitting the Striker

Adjusting the Plunger

Spanner

Plunger 
nut

the plunger to penetrate the striker face plate. 
If the plunger still fails to penetrate the striker 
face plate, the door height may need to be 
adjusted.

Plunger 
flats

Shroud 
face

Red 
section

Note: the locking slider arm may have been 

pre-cut depending on the width of the door. 

The drawing below demonstrates a cut 

slider arm.

If you are installing a handle that has 

LOCKED/UNLOCKED indication, ensure 
that the green and red Emergency Release 
Indicator Label
 has been applied with the 

RED section at the TOP.

Emergency release 
indicator label

Two 
holes

Cavity Sliders Limited 
Auckland Head Office
5 - 7 Rakino Way  
Mt Wellington
Auckland, NZ

T  +64 9 276 0800
F  +64 9 276 2525
[email protected]

Recyclable 

Packaging

www.csfordoors.co.nz

www.cavitysliders.com.au

www.cavitysliders.com

Отзывы: