CS-Lab s.c. | CSMIO-MPG manual pulse generator module 

5

 

 

1.3

 

Technical data 

 

PARAMETER  VALUE 

Digital inputs  10 

Digital outputs  2 

Analog inputs  2 

Analog outputs  0 

Supply voltage  24VDC +/-10% 

Power consumption  2W 

Maximum I/O voltage  30VDC 

Maximum I/O load  30mA 

Analog Input Voltage  0-5 VDC 

Rotary Encoder input  TTL  5V (±A/±B) 

Connection with CSMIO/IP  CAN 250kbps 

Ambient temperature range  0

o

C do +60

o

Relative humidity (Non-condensing)  10% - 95% 

 

Encoder inputs (±A/±B) allow connection to different styles of rotary encoders. See chapter 5 for more 
information. 

 

1.4

 

Changes regarding to previous version of CSMIO-MPG module 

 

The main change regarding to the previous version is lack of configuration switches. The change is due 
to implementation of optical isolation on inputs of a handwheel encoder. This way we get higher 
resistance to interferences, especially when the handwheel we use has no differential outputs. In this 
situation we need line polarization when we use handwheels without the differential outputs. On the 
configuration jumpers there was also a switch responsible for CAN bus termination. Currently there is 
a terminator included which should be plugged in if the module is the last device on the CAN bus. If we 
have only CSMIO-MPG module connected to the CAN bus, then we plug in the terminator on right DB9 
connector. 
 

2.

 

Safety 

 

The CSMIO-MPG device is powered by 24VDC low voltage. I / O control lines are optically isolated, and 
the PC connection is galvanically isolated. The device does not constitute a direct threat to the health 
or life of the user. 
When designing a complete control system, you should draw attention to all issues, so that the entire 
system does not pose any hazard during use. 
 
Pay special attention to the emergency stop circuit. The control system must be designed in such a 
way that when you press the emergency stop mushroom, the controlled machine immediately stops 
all  axes.  You should  also  consider  the possible failure  of any system components  such as  the main 
controller, or axis drives.  

 

Содержание CSMIO-MPG

Страница 1: ...copyright CS Lab s c 2019 Rev 3 0 CSMIO MPG manual pulse generator JOG module...

Страница 2: ...ngement 7 4 2 DB25 Connector 8 4 3 Connector for CSMIO IP or previous module connection 8 4 4 Connector for next expansion modules connection 9 4 5 Power supply connector 9 5 CSMIO MPG module configur...

Страница 3: ...24VDC power Digital inputs and outputs are optically isolated and filtered In the v2 version of the module also encoder inputs have an optical isolation The CSMIO MPG is enclosed in a compact enclosur...

Страница 4: ...gned and made in accordance with the national and international standards for industrial control systems based on electronic components Detailed requirements for programmable controllers working chara...

Страница 5: ...n this situation we need line polarization when we use handwheels without the differential outputs On the configuration jumpers there was also a switch responsible for CAN bus termination Currently th...

Страница 6: ...r mechanical installation Here is an example components arrangement in the control cabinet Caution is advised during the mechanical and electrical installation Poorly tightened cables may cause many p...

Страница 7: ...manual pulse generator module 7 4 Connectors 4 1 Connector arrangement MPG handwheel connector Connector for CSMIO IP or previous module Connector for next expansion modules or CAN terminator RS485 Po...

Страница 8: ...Digital input 2 x100 9 Digital input 4 Y axis 10 Digital input 6 A axis 11 Digital input 8 C axis 12 Shared power supply for 0 9 inputs 13 E Stop 2 14 GND 15 Digital output 1 16 A TTL 5V input 17 B T...

Страница 9: ...Description 1 CAN H 2 RS232 RxD 3 RS232 TxD 4 5 GND 6 CAN L 7 RS485 B 8 RS485 A 9 PIN Description 1 E Stop 1 2 E Stop 2 3 power 24V DC 4 GND 5 ground This connector is dedicated only for CS Lab expans...

Страница 10: ...CAN bus and RS485 Some expansion modulef from CSMIO devices family have termination switch of CAN bus and RS485 CSMIO MPG v2 module does not have any configuration switches and due to that it is requi...

Страница 11: ...www cs lab eu CS Lab s c CSMIO MPG manual pulse generator module 11 6 Handwheel MPG connection scheme 6 1 Handwheel MPG with differential encoder output...

Страница 12: ...www cs lab eu CS Lab s c CSMIO MPG manual pulse generator module 12 6 2 Handwheel MPG with common encoder output...

Страница 13: ...unction To do this click on the Config Ports and Pins and go to the Encoder MPG s tab and select MPG 1 From now on the module is ready to work 7 1 Multiplier range selection The basic assumed distance...

Отзывы: