20
11. BATTERY MEMORY SET
For your convenience Space X1 Turbo has a data storage
and load program, it can store 10 different battery data rep-
resent the respective specifications of batteries, you can call
back the data when charging/discharging without setting up
the program again, press START/ENTER button to make it
blink and use INC. or DEC. to set up the parameter.
The example is Lipo battery pack (2S/7.4V).
Set the voltage and number of cells, along with the normal
voltage (1S-6S).
Set the charge current, it can be adjusted (0.1-7.0A).
Set the discharge current, it can be adjusted (0.1A-2.0A).
Set the discharge voltage, it can be adjusted (3.0-3.3V/Cell).
Set the terminal voltage, it can be adjusted (4.18-4.30V)
Set the cut-off temperature, it can be adjusted(20 C/68 F-80
C/176 F).
Press the START/ENTER button more than 3 seconds to
save the program.
This screen indicate the saved profile.
Start
Enter
>3 seconds
DEC. INC.
DEC. INC.
DEC. INC.
DEC. INC.
BATT TYPE
LiPo
DSCH CURRENT
2.2A
BATT VOLTS
7.4V(2S
CHARGE CURRENT
4.9A
DSCH VOLTAGE
3.0V/CEL
Start
Enter
>3 seconds
DEC. INC.
DEC. INC.
TVC=YOUR RISK
4.20V
SAVE PROGRAM
SAVE
SAVE PROGRAM
ENTER
BATT MEMORY
【
1
】
LiPo 7.4V(2S)
BATT MEMORY
【
1
】
C:4.9A D:2.2A
ENTER CHARGER
LOAD
⋯⋯
Next flash
TEMPERATURE
CUT-OFF 50C
BATT MEMORY
【
1
】
ENTER SET