3. Installation
13
TOWARDS THE POOL
Snow tent
POOL
≥30cm
Filtration
Pump
FROM THE POOL
The filter located upstream of the heat pump must be regularly
backwashed so that the water in the system is clean, thus avoiding
the operational problems associated with dirt or clogging in the filter.
50-80cm
≥30cm
subgrade
wall
Step 1
Screw the connectors to the heat pump
Step 2
Connect the water outlet pipe and the water intake pipe
The heat pump electrical plug integrates a 10mA differential circuit breaker.
Before connecting your heat pump, please ensure that the plug is
connected to the ground.
The filter pump should function at the same time as the heat pump.
Therefore, you need to connect them to the same electrical circuit.
Model
max current(A)
maximum length of the wire(m)
Refrigerant
2
1.0mm
2
1.5mm
2
2.5mm
2
4mm
2
6mm
2
10mm
Crystal Mini 40
6.65
36
52
88
142
213
371
R32
3.
4
Electrical connection
3.
3
Hydraulic connection
3.
2
Installation layout